4-2. Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

Remedy

 

 

 

 

 

 

 

 

 

 

Completely inoperative; fan does not run.

Place line disconnect switch in the On position.

 

 

 

 

 

 

 

 

 

Check and replace open line fuse(s) (see Section 2-11).

 

 

 

 

 

 

 

 

 

Check for proper jumper link positions (see Section 2-12).

 

 

 

 

 

 

 

 

 

Check for proper input connections (see Section 2-12).

 

 

 

 

 

No weld output; fan motor FM running.

Reset circuit breakers CB1 and/or CB2, if necessary (see Section 2-10).

 

 

 

 

 

 

 

 

 

Unit overheated. Allow unit to cool with fan on (see Section 2-2).

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check control relay CR1.

 

 

 

 

 

Excessive line current; line fuse(s) and/or circuit

Check for proper input connections (see Section 2-12).

breaker(s) open repeatedly.

 

 

 

 

 

 

 

 

 

 

Check for proper jumper link positions (see Section 2-12).

 

 

 

 

 

Weld output available; fan does not run.

Check for and remove anything blocking fan blades.

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check fan motor FM.

 

 

 

 

 

Fan runs slowly.

Check for proper jumper link positions (see Section 2-12).

 

 

 

 

 

Limited output and low open-circuit voltage.

Check and replace open line fuse(s) (see Section 2-11).

 

 

 

 

 

 

 

 

 

Check for proper input connections (see Section 2-12).

 

 

 

 

 

 

 

 

 

Check for proper jumper link positions (see Section 2-12).

 

 

 

 

 

Erratic or improper weld output.

Check for proper jumper link positions (see Section 2-12).

 

 

 

 

 

 

 

 

 

Check for proper input connections (see Section 2-12).

 

 

 

 

 

 

 

 

 

Select correct size weld cables (see Section 2-8).

 

 

 

 

 

 

 

 

 

Clean and tighten weld cable connections (see Section 2-8).

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent adjust brush contact on slide wire.

 

 

 

 

 

 

 

 

 

For 250 ampere models, check tap slope connections (see Section 2-6).

 

 

 

 

 

Erratic or improper weld output. (Continued)

For 200 and 300 ampere models, check inductance connections (see Section 2-7).

 

 

 

 

 

 

 

 

 

Install wire feeder according to it’s Owner’s Manual.

 

 

 

 

 

No 115 volts ac output at Remote 14 receptacle RC8.

Reset circuit breaker CB1, if necessary (see Section 2-10).

 

 

 

 

 

No 24 volts ac output at Remote 14 receptacle RC8.

Reset circuit breaker CB2, if necessary (see Section 2-10).

 

 

 

 

 

OM-259 Page 18

Image 22
Contents Processes OM-259Description From Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explo- sion Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersLES Fumées ET LES GAZ peuvent être dangereux Signification des symbolesUN Choc Électrique peut tuer Identifie un message de sécurité particulierDES Pièces Chaudes peuvent pro- voquer des brûlures graves LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux LE Bruit peut affecter l’ouïe’EMPLOI Excessif peut Risque D’INCENDIE OULA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresInformation sur les champs électromagnétiques Principales normes de sécuritéConsignes relatives aux stimulateurs cardiaques Specifications − InstallationDuty Cycle And Overheating Volt-Ampere Curves Ampere Models 300 Ampere ModelsSelecting a Location Dimensions And WeightsDo not move or operate unit where it could tip Movement TippingSlope Selection 250 Ampere Model Slope Connection Label Tapped Reactor AC-Z And Slope CoilsInductance Selection 200 And 300 Ampere Models Remote 14 Receptacle Information Weld Output Terminals And Selecting Cable SizesARC Welding can cause Electromagnetic Interference Connecting To 115 Volts AC Duplex Receptacle Electrical Service GuidePlacing Jumper Links And Connecting Input Power Volts− Operation − Maintenance & TroubleshootingRoutine Maintenance ControlsTroubleshooting Trouble Remedy− Electrical Diagrams Circuit Diagram For 250 Ampere Model− Parts List Complete AssemblyDia Part Mkgs Description Quantity RC9 Call Miller for your local Miller distributor Owner’s Record Miller Electric Mfg. Co