Simer Pumps 3075SS, A5500, 2955-01, 2957-01 Installation / Electrical / Operation, Maintenance

Page 4

Installation / Electrical / Operation

4

5.Power Supply: These pumps are designed for 115 V., 60 Hz., operation and require a minimum 15 amp individual branch circuit. Both the pump and switch are supplied with 3-wire cord sets with grounding-type plugs. The switch plug is inserted directly into the outlet and the pump plug inserts into the opposite end of switch plug.

Hazardous voltage. Can shock, burn or cause death. Pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of elec- tric shock, be certain that it is connected only to a properly grounded, grounding type receptacle such as a grounded water pipe or a properly grounded metallic raceway or ground wire system. Ground terminal on pump cord plug is provided for your protection. DO NOT REMOVE!

A ground fault circuit interrupter is recommended for use with any electrical appliance submerged in water. For instal- lation of such a circuit, consult a licensed electrician.

6.After the piping and the check valve (if needed) have been installed, the unit is ready for operation

7.Check the operation by filling the sump with water and observing pump operation through one complete cycle.

Risk of flooding. Can cause personal injury and/or property damage. Failure to make this operational check may lead to flooding and premature failure.

OPERATION

Risk of electric shock. Shock can burn or kill. Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface, or in water.

1.Keep the pump inlet screen clear.

2.The shaft seal depends on water for lubrication. Do not operate the pump unless it is submerged in water as the seal may be damaged if the pump is allowed to run dry.

3.The motor is equipped with an automatic reset thermal pro- tector. If the temperature in the motor should rise unduly, the switch will cut off all of the power before any damage can be done to the motor. When the motor has cooled suf- ficiently, the switch will reset automatically and restart the motor. If the protector trips repeatedly, the pump should be removed and checked for the cause of the difficulty. Low voltage, long extension cords, a clogged impeller, very low head or lift, etc., could cause cycling. Refer to the Troubleshooting Chart on Page 5 for additional information.

4.Periodically inspect the pump, system components and sump for debris and foreign objects. Keep the sump free of all refuse. Perform routine maintenance as required.

Risk of flooding. Flooding can cause personal injury or property damage. This pump comes with the auto- matic float switch mounted on the motor cover ready for oper- ation. Do not change switch settings. Refer to the “Motor, Switch & Cord Specifications” chart for switch settings.

MAINTENANCE

To Clean the Pump Screen:

NOTICE: Attempting to disassemble motor will void warranty.

Risk of electrical shock. Shock can burn or kill. Always unplug the pump from the power source before servic- ing any system component. Do not lift pump by power cord.

1. Disconnect power before servicing.

Risk of Electric shock. Shock can burn or cause death. When servicing the system always disconnect power cord from the electrical outlet.

2.Loosen the discharge pipe.

3.Use the pump handle to lift the pump out of the sump pit and place the pump on a clean level surface.

4.To clean the screen, remove the three screws holding the screen to the pump base (See Figure 1), remove and rinse off the screen.

Install Switch on Pump

Anti-

Airlock

Valve

Screen

Screen screws (3)

Figure 1 – To clean the Screen and Anti-airlock Valve and to attach Float Switch.

5.Re-install the screen and the screws.

6.Put the pump back into the sump pit.

7.Re-install the discharge pipe.

8.Check the system operation by filling the basin with water and observing the pump’s operation through one complete cycle.

Flood hazard. May cause personal injury or prop- erty damage. Failure to make this operational check can lead to improper operation, premature pump failure and flooding.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 4
Contents Submersible Sump Pumps Installation/Fonctionnement/PiècesPompes de puisard submersible Safety Read and Follow Safety InstructionsGeneral Information / Installation Maintenance Installation / Electrical / OperationOperation Troubleshooting Operation / Maintenance / TroubleshootingAirlocks Repair Parts Repair Parts ListKey Part Description 2957-01 2957-03Sécurite Lire Toutes CES Instructionset LES SuivreCaractéristiques Renseignements généraux / InstallationDébits Installation / Electricité / Fonctionnement FonctionnementEntretien Pour nettoyer la crépine de la pompeFonctionnement / Entrentien / Recherche des pannes Recherche des pannesBouchons D’AIR Pour remplacer un interrupteur à flotteur verticalListe DE Pièces DE Rechange Pièces de rechangeRéf Désignation Qté 2957-01 2957-03 Seguridad LEA Y Observe LAS Instrucciones DE SeguridadInformación General / Instalación Instalación / Electridad / Operación OperaciónMantenimiento Para limpiar la criba de la bombaOperación / Mantenimiento / Localización de fallas Localización de fallasBolsas DE Aire Cómo reemplazar el interruptor de flotador verticalLista DE Piezas DE Repuesto Piezas de repuestoDescripción de La pieza
Related manuals
Manual 24 pages 60.1 Kb

2330, 2957-01, 2957, A5500, 2955-01 specifications

Simer Pumps has established itself as a trusted name in the water pump industry, providing high-quality products that cater to various applications. Among their lineup, the Simer Pumps 3075SS, 2955-01, A5500, 2957, and 2957-01 models stand out for their performance, durability, and innovative technologies.

The Simer 3075SS is a stainless steel submersible pump designed for heavy-duty applications. Its robust construction offers exceptional corrosion resistance, making it ideal for residential and commercial use in demanding environments. This pump features an efficient motor that can handle both clear and slightly contaminated water, boasting a maximum flow rate of up to 75 gallons per minute. The automatic float switch ensures hands-free operation, activating the pump when water reaches a predetermined level.

The Simer 2955-01 is another reliable option, perfect for draining basements, flooded areas, or swimming pools. This submersible utility pump is lightweight and easy to transport, yet it doesn't compromise on efficiency. With a maximum flow rate of 30 gallons per minute, the 2955-01 is equipped with a powerful motor that enables continuous operation. The built-in overload protection safeguards the pump from potential damage, extending its lifespan.

Next in the lineup is the Simer A5500, a versatile high-capacity utility pump designed for more demanding applications. With its durable construction, this pump can handle larger volumes of water, making it suitable for commercial and industrial settings. The A5500 boasts a maximum pumping capacity of 70 gallons per minute, and its rugged design enables it to operate effectively in both fresh and saltwater environments. This model also comes with a thermal overload switch that provides additional protection against overheating.

The Simer 2957 and 2957-01 models are designed with user convenience in mind. These submersible pumps guide water away from flooded areas efficiently. They provide a maximum flow rate of 30 gallons per minute and feature an adjustable float switch for customizable operation. The lightweight design makes them easy to transport, while the thermoplastic construction ensures longevity and resistance to corrosion.

In conclusion, Simer Pumps' models 3075SS, 2955-01, A5500, 2957, and 2957-01 exemplify the company’s commitment to quality and reliability. With their robust construction, intuitive features, and advanced technologies, these pumps meet the diverse needs of consumers and professionals alike, ensuring efficient water management across various applications.