Simer Pumps 5020B-04 owner manual Description, Specifications, Performance, General Safety

Page 3

Safety

3

DESCRIPTION

This Pedestal Sump Pump is designed for home sumps. Unit is equipped with a 3-prong grounding- type power cord. Sleeve bearings on motor shaft never need lubrication. Automatic reset thermal protection. NOTICE: This unit is not designed for applications involving salt water or brine! Use with salt water or brine will void warranty.

SPECIFICATIONS

Power supply required

115V, 60 HZ.

Horsepower

1/3

Motor duty

Intermittent

Liquid Temp. Range

32°F to 70°F(0°-21°C)

Individual Branch Circuit

 

 

Required GFCI Class A

15

Amps

Motor full load (maximum)

3.5

Amps

Discharge:

1-1/4" FNPT

PERFORMANCE

GPH (LPH) AT TOTAL FEET (M)

5 Ft.

10 Ft.

15 Ft.

20 Ft.

(1.52)

(3.05)

(4.57)

(6.09)

 

 

 

 

3000

2460

1620

0

(11 355L)

(9 312L)

(6 131L)

(0L)

 

 

 

 

GENERAL SAFETY

Electrically powered sump pumps normally give many years of trouble-free service when correctly installed, maintained, and used. However, unusual circum- stances (interruption of power to the pump, dirt/debris in the sump, flooding that exceeds the pump’s capaci- ty, electrical or mechanical failure in the pump, etc.) may prevent your pump from functioning normally. To prevent possible water damage due to flooding, con- sult your retailer about a secondary AC sump pump, a DC backup sump pump, and/or a high water alarm. See the “Troubleshooting Chart” in this manual for information about common sump pump problems and remedies. For more information, see your retailer or call Simer customer service at 1-800-468-7867.

1.Know the pump application, limitations, and potential hazards.

Do not use in explosive atmospheres. Pump water

only with this pump. Failure to follow this warn- ing can result in personal injury and/or property damage.

2.Disconnect power before servicing.

3.Release all pressure within system before servic- ing any component.

4.Drain all water from system before servicing.

Risk of flooding. If a flexible dis- charge hose is used, pump may move when motor starts. If it moves far enough so

that switch hits side of sump, switch may stick and prevent pump from starting.Make sure pump is secured so it cannot move around in sump.

5.Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.

6.Check hoses for weak or worn condition before each use, making certain all connections are secure.

7.Inspect sump, pump and system components monthly. Keep free of debris and foreign objects. Perform routine maintenance as required.

FIRE HAZARD - Do not store or rest objects on or near

motor or switch linkage. Keep all flammable objects or liquids away from motor.

8.Provide means of pressure relief for pumps whose discharge line can be shut-off or obstructed.

9.Personal Safety:

a.Wear safety glasses at all times when work- ing with pumps.

b.Keep work area clean, uncluttered and properly lighted – replace all unused tools and equipment.

c.Keep visitors at a safe distance from work area.

d.Make workshop child-proof – with pad- locks, master switches, and by removing starter keys.

10.When wiring an electrically driven pump, fol- low all electrical and safety codes, as well as most recent National Electrical Code (NEC) and Occupational Safety and Health Act (OSHA).

11.This equipment is only for use on 115 volt (sin- gle phase) and is equipped with an approved 3- conductor cord and 3-prong, grounding-type plug.

To reduce risk of electric shock, be certain that it is

connected to properly grounded, grounding- type receptacle.

Never connect green (or green and yellow) wire in

cord to a live terminal!

Where a 2-prong wall receptacle is encoun- tered, it must be replaced with properly grounded 3-prong receptacle installed in accor- dance with the National Electrical Code and local codes and ordinances.

12.All wiring should be performed by a qualified electrician.

13.Make certain that power source conforms to requirements of your equipment.

14.Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking cord. Replace or repair damaged or worn cords immediately.

15.Do not touch an operating motor. Modern motors are designed to operate at high temper- atures.

16.Do not handle pump or pump motor with wet hands or when standing on wet or damp sur- face, or in water.

If your basement has water or moisture on floor, do not walk on

wet area until all power has been turned off. If shut-off box is in basement, call electric company to shut-off service to house, or call local fire department for instructions. Remove pump and repair or replace. Failure to follow this warning can result in fatal electrical shock.

Do not use in hazardous or explosive locations.

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Image 3
Contents Pages MOD B-04Call Llame alRetain Original Receipt for Your Records WarrantyDescription SafetySpecifications General SafetyInstallation Installation / OperationTroubleshooting OperationOperation 5020B-04 Repair PartsSwitch FP0018-7D Key Part DescriptionPompes D’EAUX D’ÉGOUT GarantieSécurité Caractéristiques TechniquesRendement La pompe doit être à niveau la colonne doit être verticale Installation / FonctionnementDébrancher la pompe avant de travailler sur la pompe Diagnostic des pannesFonctionnement FonctionnementPièces de rechange Réf Désignation des pièces Qté 5020B-04Interrupteur FP0018-7D Bombas Cloacales GarantíaRendimiento SeguridadDescripción EspecificacionesInstalación Instalación / FuncionamientoSolución de problemas FuncionamientoFuncionamiento Refacciones Descripción Cant 5020B-04Interruptor FP0018-7D

5020B-04 specifications

Simer Pumps has long been known for its reliable and efficient pumping solutions, and the Simer Pumps 5020B-04 model stands out as a prime example of the brand's commitment to quality and performance. Designed primarily for residential and light commercial applications, this pump offers a host of features and advanced technologies to meet a variety of pumping needs.

One of the defining characteristics of the 5020B-04 is its robust construction. Built with durable materials, the pump is designed to withstand both the rigors of daily use and the environmental challenges it may face. The housing is resistant to corrosion, ensuring longevity even in harsh conditions. This reliability makes it a valuable addition to any homeowners' toolkit or commercial setup.

The Simer Pumps 5020B-04 is powered by a high-performance motor that provides substantial horsepower while maintaining energy efficiency. With a power rating of 1/2 HP, the pump is capable of handling moderate to heavy workloads with ease. It operates smoothly, minimizing noise and vibrations, which is especially important for residential users looking to maintain a peaceful environment.

In terms of technology, the 5020B-04 utilizes a robust thermal overload protection system. This feature prevents the motor from overheating, significantly extending the life of the pump and minimizing maintenance costs. Additionally, the pump is equipped with an innovative float switch design that ensures automatic operation; it turns on and off based on the water level, making it hassle-free for users.

Another key characteristic of the Simer Pumps 5020B-04 is its versatility. It is suitable for a range of applications, including sump pumping, draining flooded areas, and managing water in basements. The pump can handle solid particles up to a specified size, allowing it to manage dirty water effectively without compromising performance.

The compact design of the 5020B-04 makes it easy to install and maneuver, even in tight spaces. This user-friendly aspect, combined with its reliable functionality, makes it an excellent choice for homeowners and contractors alike.

In conclusion, the Simer Pumps 5020B-04 stands as a testament to the brand's dedication to quality engineering. With its durable construction, efficient motor, advanced thermal protection, and versatile application, this pump is designed to deliver exceptional performance and reliability, catering to a wide range of pumping needs. Whether for residential or light commercial use, the 5020B-04 is an investment in efficiency and dependability.