Miller Electric MSC-2 Remote Movement Control Connections, Installing Gun Onto Mounting Plate

Page 12

3-3. Remote Movement Control Connections

4

A

B

C

D

E

FF is circuit common

GG to F = Up

HH to F = Down

JJ to F = Right

KK to F = Left

Tools Needed:

4

3

2

Slide movement can be controlled by a remote device having a set of normally-open contacts. Timing of the contact closure is controlled by the remote device.

1MSC-2 Control Open control door.

2Strain Relief

3Cord From Remote Device Crimp proper terminals onto leads.

4Terminal Strip 1T

Make connections, tighten strain relief, and close and secure door.

1

ST-154 577

3-4. Installing Gun Onto Mounting Plate

A remote gun mount can be used to install gun to slide.

 

1

Gun Mounting Plate

 

2

4-1/4 in. (108 mm)

 

3

4-1/4 in. (108 mm)

 

4

3/8–16 UNC Tapped Holes

1

Do not use screws longer than 1/2

 

in. (13 mm) to secure gun to plate.

 

 

 

2

4

3

Ref. ST-154 578

OM-1096 Page 8

Image 12
Contents OM-1096 ProcessesDescription From Miller to You Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersSpecifications Motorized Slide SpecificationsMSC-2 Specifications Load DataMotorized Slide Dimensions MSC-2 DimensionsInstallation Interconnecting And Power Cord InstallationLocation Installing Gun Onto Mounting Plate Remote Movement Control ConnectionsOperation MSC-2 ControlMaintenance & Troubleshooting Motorized Slide Limit SwitchRoutine Maintenance Overload ProtectionSlide Maintenance Drive Belt AdjustmentTroubleshooting Trouble RemedyCircuit Diagram For Motorized Slide Circuit Diagram For MSC-2Parts List Motorized SlideDia Part MSC-2, Motorized Slide Control Optional OM-1096 Service SupportOwner’s Record Miller Electric Mfg. Co