3-3. Remote 14 Receptacle RC14 Information and Connections
1
|
|
|
| 4 |
| A K | J I | 5 | |
| B |
|
|
|
| C | L N | H |
|
| D | M | G |
|
|
| E | F |
|
2 | 3 |
|
| |
|
|
|
1Front Panel
2Plug
3Threaded Collar
4Keyway
5Remote 14 Receptacle RC14 (See Section
To connect to receptacle, align key- way, insert plug, and tighten threaded collar.
|
| sb7.1* 3/93 - Ref. | |
| |||
|
|
| |
| Socket | Socket Information | |
|
|
| |
Remote Contactor | A | +24 volts dc. | |
B | Contact closure to A completes 24 volts dc contactor control circuit. | ||
| |||
|
|
| |
| C | Command reference; +10 volts dc. | |
Remote Output Control | D | Control circuit common. | |
E | Input command signal (potentiometer wiper or 0 to +10 volts dc). | ||
| |||
| G | Not used. | |
|
|
| |
Power Source Limit | F, J | Absence of internal contact closure between F and J signals power source failure to remote | |
control device. | |||
|
| ||
|
|
| |
| H | Coil loss compensation value. | |
| I | Actual frequency output signal (1 volt/10 kHz). | |
Remote Metering | L | Average power output signal (1 volt/5 kW). | |
M | Voltage output signal RMS (1 volt/100 volts). | ||
| |||
| N | Current output signal RMS (1 volt/100 amperes). | |
| K | Chassis common. | |
|
|
|