5-10. Connecting To Remote 14 Receptacle RC14
OR
803 231
Socket* | Socket Information |
A24 volts ac. Protected by sup- plementary protector CB5.
24 VOLTS AC
B | Contact closure to A completes |
| 24 volt ac contactor control |
| circuit. |
COutput to remote control:+10 volts dc in MIG or Stick mode; 0 to +10 volts dc in TIG mode.
REMOTE | D | Remote control circuit common. |
|
| |
OUTPUT |
|
|
CONTROL | E | DC input command signal: 0 to |
|
| +10 volts from min. to max. of |
|
| remote control with Voltage/ |
|
| Amperage Adjust control at |
|
| max. |
|
| 115 volts, 10 amperes, 60 Hz |
| I | ac. Protected by supplementary |
115 VOLTS AC |
| protector CB6. |
|
| |
|
| Contact closure to I completes |
J115 volt ac contactor control circuit.
GND | K | Chassis common. |
|
| |
|
|
|
NEUTRAL | G | Circuit common for 24 and 115 |
|
| volt ac circuit. |
*The remaining sockets are not used.