Miller Electric OM-4409 manual Servicing Engine Fuel And Lubrication Systems, Wipe up spilled fuel

Page 53

9-7. Servicing Engine Fuel And Lubrication Systems

Tools Needed:

3

1

Right Side

 

4

5

7

6

2

! Stop engine and let cool.

! After servicing, start engine and check for fuel leaks. Stop engine, tighten connections as necessary,

base. Be sure to select the correct hose when draining engine oil.

Route engine oil drain hose through hole in base. See engine manual and engine main- tenance label for oil specifications.

To replace secondary fuel filter:

See engine manual.

Close doors.

To drain sludge from fuel tank:

803 228

and wipe up spilled fuel.

1Oil Filter

2Oil Drain Hose And Valve

3Oil Fill Cap

4Primary Fuel Filter (Fuel/Water Separator)

5Petcock

6Secondary Fuel Filter

7Fuel Tank Sludge Drain Valve

To change oil and filter:

.The engine oil drain and compressor oil drain hoses are located together in the

To drain water from fuel system:

Open primary fuel filter petcock and drain water into metal container. Close petcock when water-free fuel flows.

To replace primary fuel filter:

Turn filter counterclockwise. Remove filter.

Apply thin coat of fuel to gasket on new filter. Fill filter with fuel. Install filter and turn clock- wise until tight. Bleed air from fuel system according to engine manual.

Inspect fuel lines, and replace if cracked or worn.

!Beware of fire. Do not smoke and keep sparks and flames away from drained fuel. Dispose of drained fuel in an environmentally-safe manner. Do not leave unit unattended while draining fuel tank.

! Properly lift unit and secure in a level position. Use adequate blocks or stands to support unit while drain- ing fuel tank.

Attach 1/2 ID hose to drain valve. Put metal container under drain, and use screwdriver to open sludge drain valve. Close valve when sludge has drained. Remove hose.

OM-4409 Page 49

Image 53
Contents Processes OM-4409206Description File Engine DriveFrom Miller to You Table of Contents − Troubleshooting − Operating Optional Battery ChargerTroubleshooting Tables − Parts ListArc Welding Hazards Symbol UsageElectric Shock can kill HOT Parts can cause severe burnsBuildup of GAS can injure or kill Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionCompressed Air Hazards Engine HazardsHOT Parts can cause burns and injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryCalifornia Proposition 65 Warnings Principal Safety StandardsEMF Information Radiation can cause interference− Consignes DE Sécurité − Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer Indique des instructions spécifiquesLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut affecter l’ouïeDES Organes Mobiles peuvent pro voquer des blessures ’EXPLOSION DE LA Batterie peuRisque D’INCENDIE OU D’EXPLO- Sion LA Chaleur DU Moteur peut pro- voquer un incendie’AIR Comprimé peut provoquer des blessures DES Organes Mobiles peuvent provoquer des blessures LE Surchauffement peut endom- mager le moteur électriqueLES Fils DE Soudage peuvent provoquer des blessures ’EMPLOI Excessif peutPrincipales normes de sécurité Proposition californienne 65 AvertissementsInformation EMF En ce qui concerne les implants médicaux− Definitions Symbols And DefinitionsWeld, Power, And Engine Specifications − SpecificationsAir Compressor Specifications Sound Level TableLifting Eye Weight Rating Dimensions, Weights, And Operating AnglesWeight AC Stick Mode Optional DC Stick ModeMIG Mode Stick And MIG Volt-Ampere CurvesTIG Volt-Ampere Curves DC TIG ModeAC TIG Mode Optional Duty Cycle And Overheating Fuel Consumption100% Duty Cycle At 500 Amperes 40% Duty Cycle At 600 AmperesGenerator AC Power Curve 20 kVA/kW Three-Phase AC Output No Weld Load Optional 3-Phase Generator Power Curves12 kVA/kW Single-Phase AC Output No Weld Load Air Compressor Output Curve Optional Battery Charging Output CurveManufacturing Rating Label Installing Welding Generator − InstallationLocation/Airflow Clearance Grounding1Supporting The Unit Mounting Welding GeneratorMounting Surface To Bolt Unit In PlaceMount the muffler with the clean- out plug to the outside Installing Optional Spark Arrestor MufflerStop engine and let cool Be sure to tighten rain cap mounting screwConnecting The Battery Activating The Dry Charge Battery If ApplicableDo not overfill battery cells Reinstall cover after connecting batteryStop engine Using The Optional Battery Disconnect SwitchSwitch may be locked using a customer-supplied padlock Engine/Compressor Prestart Checks MIG And Fcaw Welding Connecting To Weld Output TerminalsStick And TIG Welding 150 ft 200 ft 250 ft Connecting to weld Output terminalsSelecting Weld Cable Sizes Socket Connecting To Remote 14 Receptacle RC14Open Position Closed Position Connecting To The Air CompressorControls See Section − Operating the Welding GeneratorDescription Of Controls See Section Process/Contactor Switch Settings Process/Contactor SwitchExample Combination Remote Amperage Control TIG Using Remote Voltage/Amperage ControlExample Combination Remote Amperage Control Stick Volt And 240 Volt Receptacles − Operating Auxiliary EquipmentAt least once a month, run en Is working properlyConnecting To Optional AC Power Plant Supplementary Protector CB2 Supplementary Protector CB3 Optional Generator Power Receptacles240 V 15 a AC South African Receptacle RC1 Battery Charge Controls − Operating Optional Battery ChargerDetermining Battery Charging Current Output Selector SwitchBattery Charge Cable Connections To control battery charging output using a Battery Charging ProcedureCharge battery for 10 minutes before jump starting battery Jump Starting ProcedureConnect Remote Or Control Device Momentary-On Switch CablesEngine Maintenance Label − ENGINE/GENERATOR MaintenanceRoutine Engine/Generator Maintenance Checking Generator Brushes Material Thickness Reference ChartAir cleaner primary element can Servicing Engine Air CleanerTo clean air filter Optional Keep nozzle 2 in 51 mm from elementReinstall cleanout plug Tools Needed Inspecting/Cleaning Optional Spark Arrestor MufflerDo not set engine speed higher than specified Adjusting Engine SpeedWipe up spilled fuel Servicing Engine Fuel And Lubrication SystemsTo change oil and filter To drain water from fuel systemEngine/Generator Overload Protection Air Compressor Maintenance Label − AIR Compressor MaintenanceRoutine Air Compressor Maintenance Compressor Air Cleaner Servicing Compressor Air CleanerRemove engine air cleaner cover Reinstall primary element and cover dust ejector downSee -8for engine/genera- tor overload protection Compressor Overload ProtectionTo change compressor oil and filter Servicing Air CompressorEngine oil drain and compressor oil To replace air/oil separatorAdjusting Compressor Air Pressure Welding − TroubleshootingTroubleshooting Tables Optional AC Power Plant Standard Generator PowerEngine Air Compressor Optional Battery ChargingCircuit Diagram For Air Compressor − AIR Compressor DiagramCircuit Diagram For Welding Generator − Circuit Diagram221 915−C Welding Generator − RUN-IN ProcedureWetstacking From flammables Run-In Procedure Using Load BankOutput and do not exceed duty Cycle or equipment damage mayRun-In Procedure Using Resistance Grid Flow Of Free Air CFM Through Orifices Of Various Diameters − AIR Compressor TablesSec 15 sec 21 sec Grounding Generator To Truck Or Trailer Frame − Generator Power GuidelinesSelecting Equipment How Much Power Does Equipment Require? Grounding When Supplying Building SystemsUse ground device as stated in electrical codes Amperes x Volts = WattsApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Amperage Range Gas Type Polarity Preparing Tungsten For DC Electrode Negative Dcen WeldingPreparing Tungsten For AC Welding Positioning The Torch − Guidelines for TIG Welding GtawTungsten Without Filler Rod Torch Movement During WeldingWelding direction Form pool Tilt torch Tungsten With Filler RodButt Weld And Stringer Bead Joint Lap Joint Corner Joint Positioning Torch Tungsten For Various Weld JointsHardware is common and not available unless listed − Parts List133 148 147 126121 109 120 122 108 102 103 105 106 107 7273 Dia Part Description Quantity Mkgs 224265 199505 CT1 C1/D1 21 22CB11,CB12,CB13 2724 40 39 Hardware is common Not available unless listedCB2 Fuel Generator -1Item Generator172555 Main Rectifier Assembly 10 9 1516 8281 7371 Air Compressor AssemblyAir Compressor Assembly -1Item Clutch Support ServiceYour distributor also gives Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s

OM-4409 specifications

The Miller Electric OM-4409 is a remarkable welding machine designed for both professional welders and enthusiastic hobbyists. Known for its reliability and efficiency, the OM-4409 stands out in the industrial landscape due to its advanced features and innovative technologies.

One of the main features of the OM-4409 is its impressive power output. With a rated output of 400 amps, it is capable of tackling a variety of welding applications, including MIG, TIG, and stick welding. This versatility allows users to switch between welding processes depending on the project requirements while ensuring consistent quality and performance.

The machine incorporates advanced inverter technology, which enhances its overall efficiency. Inverter technology allows for a compact design without sacrificing performance. The OM-4409 weighs significantly less than traditional transformer-based machines, making it more portable and easier to transport. Additionally, the inverter technology ensures that energy consumption is kept to a minimum, reducing operational costs.

Another notable characteristic of the Miller Electric OM-4409 is its user-friendly interface. The intuitive control panel provides easy access to settings and adjustments, allowing welders to fine-tune the machine to their specific needs. The digital display shows crucial parameters such as voltage, amperage, and wire feed speed, enabling welders to monitor their progress in real-time effectively.

Safety is paramount in industrial applications, and the OM-4409 does not disappoint. It is equipped with advanced safety features, including thermal overload protection and fault indication systems. These features ensure that the machine operates within safe limits, protecting both the user and the equipment.

The OM-4409 also boasts a robust build quality, designed to withstand the rigors of daily use in demanding environments. Its durable construction ensures longevity, minimizing maintenance and downtime.

In summary, the Miller Electric OM-4409 welding machine is a powerhouse that combines power, efficiency, and user-friendliness. With its inverter technology, versatility across various welding processes, advanced safety features, and robust design, it represents an excellent investment for any welding professional looking to enhance their capabilities. Whether for heavy-duty industrial applications or intricate metalwork, the OM-4409 delivers unmatched performance and reliability.