Simer Pumps 2944RP owner manual Troubleshooting Chart

Page 6

Troubleshooting

6

TROUBLESHOOTING CHART

 

 

 

 

SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

 

 

 

Pump won’t start or run.

Pump is not plugged in.

Check and see if pump is plugged in to a proper outlet.

 

Blown fuse.

If blown, replace with fuse of proper size.

 

Low line voltage.

If voltage under recommended minimum, check size of wiring

 

 

from main switch on property. If OK, contact power company

 

 

or hydro authority.

 

Defective motor.

Replace pump.

 

Defective float switch.

Replace float switch.

 

Impeller.

If impeller won’t turn, remove lower pump body and locate

 

 

source of binding.

 

Float obstructed.

Remove obstruction.

 

 

 

Pump starts and stops

Backflow of water from piping.

Install or replace check-valve.

too often.

Faulty float switch.

Replace float switch.

 

 

 

 

Pump won’t shut off.

Defective float switch.

Replace float switch.

 

Restricted discharge

Remove pump and clean pump and piping.

 

(obstacle or ice in piping).

 

 

Float obstructed.

Remove obstruction.

 

Restricted intake screen.

Remove the pump and clean the intake screen and the

 

 

impeller.

 

 

 

Pump operates but

Low line voltage.

If voltage under recommended minimum, check size of wiring

delivers little or no water.

 

from main switch on property. If OK, contact power company

 

 

or hydro authority.

 

Something caught in impeller.

Remove the pump and clean out the impeller.

 

Worn or defective parts or

Clean impeller if plugged; otherwise replace pump.

 

plugged impeller.

 

 

Vent hole plugged.

Use a nail or paperclip to open vent hole in discharge pipe.

 

Restricted intake screen.

Remove the pump and clean out the intake screen.

 

Check valve is installed either

Be sure check valve is installed correctly.

 

backward or upside down.

 

 

 

 

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 6
Contents Quick Install Sump Pump General Safety Information Specifications and SafetySpecifications DescriptionPump should always be elec- trically grounded to a suit Installation and OperationInstallation Failure to make this opera- tional check may lead toOperation OperationKey Part Description Repair PartsModel 2944RPTroubleshooting Troubleshooting ChartWarranty Exceptions to the Twelve 12 Month Limited Warranty ProductGeneral Terms and Conditions Caractéristiques et Sécurité CaractéristiquesRendement Installation Ne pas lever la pompe par son cordon électriqueFonctionnement FonctionnementPièces de rechange ModèleRéf Désignation Qté 2944RP Diagnostic des pannes Localisation DES PannesGarantie Exceptions à la garantie limitée de douze 12 mois ProduitModalités et conditions générales Especificaciones Especificaciones y SeguridadDescripcion RendimientoTensión peligrosa. Puede causar InstalaciónInstalacion El incumplimiento de esta ver- ificación del funcionamientoFuncionamiento FuncionamientoRefacciones ModeloDescripción Solución de problemas Guía Para LA Resolución DE ProblemasGarantia Términos y condiciones generales