Troubleshooting | 6 | |
TROUBLESHOOTING CHART |
| |
|
|
|
SYMPTOM | PROBABLE CAUSE(S) | CORRECTIVE ACTION |
|
|
|
Pump won’t start or run. | Pump is not plugged in. | Check and see if pump is plugged in to a proper outlet. |
| Blown fuse. | If blown, replace with fuse of proper size. |
| Low line voltage. | If voltage under recommended minimum, check size of wiring |
|
| from main switch on property. If OK, contact power company |
|
| or hydro authority. |
| Defective motor. | Replace pump. |
| Defective float switch. | Replace float switch. |
| Impeller. | If impeller won’t turn, remove lower pump body and locate |
|
| source of binding. |
| Float obstructed. | Remove obstruction. |
|
|
|
Pump starts and stops | Backflow of water from piping. | Install or replace |
too often. | Faulty float switch. | Replace float switch. |
| ||
|
|
|
Pump won’t shut off. | Defective float switch. | Replace float switch. |
| Restricted discharge | Remove pump and clean pump and piping. |
| (obstacle or ice in piping). |
|
| Float obstructed. | Remove obstruction. |
| Restricted intake screen. | Remove the pump and clean the intake screen and the |
|
| impeller. |
|
|
|
Pump operates but | Low line voltage. | If voltage under recommended minimum, check size of wiring |
delivers little or no water. |
| from main switch on property. If OK, contact power company |
|
| or hydro authority. |
| Something caught in impeller. | Remove the pump and clean out the impeller. |
| Worn or defective parts or | Clean impeller if plugged; otherwise replace pump. |
| plugged impeller. |
|
| Check valve installed without | Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump |
| vent hole. | discharge & check valve |
|
| pipe screws into the pump discharge and below the |
|
| waterline). |
| Restricted intake screen. | Remove the pump and clean out the intake screen. |
| Check valve is installed either | Be sure check valve is installed correctly. |
| backward or upside down. |
|
|
|
|