Hilti TE3000-AVR operating instructions Operation, Preparing for use, Fitting the insert tool 4

Page 15

7. Operation

DANGER

Always hold the power tool securely with both hands on the grips provided. Keep the grips dry, clean and free from oil and grease.

7.1 Preparing for use

CAUTION

Wear protective gloves when changing insert tools as the insert tools get hot through use and they may have sharp edges.

CAUTION

When changing insert tools, take care to handle the locking mechanism correctly. You may otherwise risk pinching your fingers.

CAUTION

Avoid body contact with the guide tube as this part gets hot through use of the power tool.

7.1.1 Fitting the insert tool 4 5

NOTE

Use an insert tool of a length suitable for your body height.

1.Disconnect the mains plug from the power outlet.

2.Check that the connection end of the chisel is clean and lightly greased. Clean it and grease it if necessary.

3.Check that the chuck and locking bar are clean and undamaged.

4.Push the insert tool into the chuck and pivot the retaining bar to locking position A for insert tools with a collar or to locking position B for insert tools with a groove (position the chisel so that the groove is facing locking position B).

NOTE Insert tools with a combined connection end (with collar and groove) can be locked in position A or B, as desired.

5.Check that the chisel has engaged correctly by pulling it.

7.1.2 Removing the chisel

DANGER

Do not lay a hot insert tool down on flammable materials. This could cause the material to ignite, resulting in a fire.

1.Disconnect the mains plug from the power outlet.

2.Open the locking bar by pivoting it approx. 90°.

3.Pull the chisel out of the chuck.

7.2Operation

CAUTION

Working on the material may cause it to splinter.

Wear eye protection and protective gloves. Wear breathing protection if no dust removal system is used. Splintering material presents a risk of injury to the eyes and body.

CAUTION

The work generates noise. Wear ear protectors. Exposure to noise can cause hearing loss.

CAUTION

Take care to stand in a secure position, especially when chiseling breaches in floors, walls or ceilings, and wear protective gloves and safety footwear. The power tool may pull you off balance if you break through suddenly.

CAUTION

Improve the blood circulation in your fingers by relaxing your hands and exercising your fingers during breaks between working.

CAUTION

Take care to ensure that the locking bar is in the correct position in accordance with the information provided in the operating instructions and check that the insert tool is held securely (check by pulling the insert tool). Secure the area below the working area.

en

9

Image 15
Contents TE3000-AVR Page Page Page Page TE-H28P SM TE-H28P FM General information ContentsParts, operating controls and indicators Safety notices and their meaningUse of the product as directed SymbolsDescription Obligation signsChuck Protective featuresIndicator LED Using extension cordsDesignation Width mm Accessories, consumablesUsing extension cords outdoors Using a generator or transformerRated voltage 120 Technical dataSafety instructions Power toolPersonal safety Power tool use and careService Always work from a secure, safe stance Electrical safety Transport Before usePersonal protective equipment Use of extension cords and generators or transformersOperation OperationPreparing for use Fitting the insert tool 4Care and maintenance Fault Possible cause Remedy TroubleshootingService indicator Checking the power tool after care and maintenanceDisposal Manufacturer’s warranty tools426347