Variable speed drives/frequency converters

Variable speed drives/ frequency converters

Each Husqvarna PG 680 & 820 is equipped with 2 variable speed drive or frequency converter. This unit is incorporated into the machine for the following reasons:

1. Functional

Manipulate incoming power to enable increase/ decrease in speed & direction change.

Regulate current and voltage supply to the motors to ensure motors run at optimum levels (e.g. torque boost).

2.Protection/Diagnostic Protection

Monitors incoming power to ensure suitability for machine and application being performed.

Controls current being drawn by motors to ensure motors are running within safe operational limits (to prevent damage to motor).

Monitors load on machine to ensure the grinder is

not being overloaded thus offering protection for belt, bearings and other internal components.

Protects motors from faulty power supply (e.g. run- ning on 2 phases).

Diagnostic

Identifies electrical faults with the machine and registers fault code.

Has monitoring menus that help isolate cause of potential electrical faults.

Monitoring menus also enable operator to gauge how hard machine is working. Whilst it is not essen- tial for an operator to intimately know every feature of the variable speed drives or frequency convert- ers, it is useful to be familiar with both the fault codes as well as some of the monitoring menus.

Keypad/Display

Each variable speed drive or frequency converter has a keypad which will appear as illustrated on the right when the machine has power connected to it.

1.8.

2.

7.

4. 3. 5. 6.

Keypad display

1.Run direction (fwd or rev)

2.Indicates if unit is either stopped or running

3.Up key

4.Left key

5.Down key

6.Reset button

7.Output mode (Hertz in this example)

8.Output value

English - 13

Image 11
Contents Manuel d’utilisation Operator’s manualManual de instrucciones BedienungsanweisungEnglish ContentsKey to symbols Safety Instructions Storage IntroductionTransportation What is what Control panel Setting Speed and direction Setting up/OperationPowering up machine REV Application Planetary Grinding discDirection Speed FWDChanging Changing the diamondsPreparation Keypad/Display Protection/Diagnostic ProtectionFunctional Monitor screen Information provided Variable speed drives/frequency convertersMenus and information they provide Fault HistoryFault Code Possible Cause Action Faults and trouble shootingOnto Problem Possible Cause Potential SolutionSummary of diamond principles DiamondsBackground General PrinciplesGrinding disc set-up Diamond selectionApplication Full set is best Half set is best Full and half sets of diamondsHALF-SET of Diamonds FULL-SET of DiamondsHard Selecting the correct diamonds for your applicationSoft MediumDetermining the hardness of concrete CONVENTIONAL/DEMOLITION Heads MaintenanceGrinding heads Spring Steel Heads DiagramPlanetary Drive System Grinding Heads Drive SystemRemove this bolt Maintenance schedule Action Frequency Maintenance scheduleTechnical Data EC-declaration of conformity ´z+R~@¶0R¨ 2007-08-23´z+R~@¶0R¨