Maintenance schedule
Maintenance schedule
Item | Action | Frequency |
Check that head locks | Tighten head locks and | Daily |
are tight. | pound if required (Suggested |
|
| Loctite 680) |
|
Inspect heads for slop/ | Examine machine heads while machine tipped back. | Daily |
broken “fingers” if using | Disconnect Planetary Drive motor (small motor) and run |
|
spring steel heads. | discs at lowest speed. Check to see how concentric/true |
|
| grinding heads are running. |
|
Check effectiveness of | Remove planetary head motor/gearbox system and | Weekly |
planetary seal. | check for presence of dust under machine cover . |
|
Check condition of | Remove planetary head motor/gearbox system and in- | Weekly with Planetary Seal |
chain ring. | spect chain links in chain ring. Ensure links are clean and |
|
| free from |
|
|
|
|
Check condition of | Remove planetary head motor/gearbox system and | Weekly with Planetary Seal |
Drive Sprocket. | inspect condition of planetary drive sprocket. |
|
Inspect internal compo- | Remove belt tensioner cover plate and check inside | 6 monthly |
nents of machine. | machine for dust, moisture or belt fragments. Ensure to |
|
|
| |
Clean contents of elec- | Blow out inside of electrical cabinet and variable speed | Every 2 months |
trical cabinet. | drives or frequency converters with DRY compressed air. |
|
IMOPRTANT!
Prior to removing belt tensioner cover plate, ensure cover plate and area surrounding cover plate are totally clean. Avoid debris from enter- ing into inside of machine.