4.If the miter slot is not parallel loosen the two socket head cap screws (A, Fig. 13) and adjust for parallel. Tighten the two screws when the adjustment is complete.
5.Always maintain a gap of approximately 1/16” between the table edge and disc. Once the table is square and parallel to the disc adjust the 90° stop. Loosen hex nut (B, Fig. 13) and tighten the set screw (C, Fig.
13)until it contacts the trunnion. Tighten hex nut.
6.If the pointer does not line up with the “0” on the scale loosen the screw and adjust for “0”. Tighten the screw.
7.The table can be tilted between
handle. Always maintain a gap of approximately 1/16” between the table edge and disc.
Note: The belt table can be removed and the disc table can be used in its place. There are two holes in the base below the sanding belt that will accommodate the disc table’s support rod and locking handle.
Sanding Disc Replacement
1.Disconnect machine from the power source.
2.Loosen the handle (C, Fig. 14) and remove the table assembly (A, Fig. 14).
3.Turn the knob (B, Fig. 14) and open the door.
4.Remove old sanding disc by striping from wheel. Make sure the disc plate is clean.
5.Press the new disc firmly into place.
Center Point
The center point (A, Fig. 15) provided with the sander can be used for sanding circles. The center point can be locked in position by tightening the set screws (B, Fig. 15).
On/Off Switch
The machine can be turned on by moving the switch (C, Fig. 15) to the up position. The key (D, Fig. 15) can be removed when the machine is in the off position. With the key removed the switch will not operate.