Desa BTU/HR owner manual Service Procedures, Continued, Disconnecting Ignitor Wires

Models: BTU/HR

1 32
Download 32 pages 60.98 Kb
Page 11
Image 11
IGNITOR

SERVICE PROCEDURES

Continued

IGNITOR

1.Remove upper shell and fan guard (See Up- per Shell Removal, page 9).

2.Remove fan (see page 9).

3.Remove 4 side cover screws with a 5/16" nut driver. Remove side cover (see Figures 18 or 19, page 10).

4.Disconnect ignitor wires from ignition con- trol assembly (see Figure 20). Pull the ignitor wires up through the hole in the lower shell.

5.Disconnect fuel line hose and air line hose. Remove photocell from photocell bracket (see Figure 20).

6.Remove combustion chamber. Stand combus- tion chamber on end with nozzle adapter bracket on top (see Figure 21 or 22).

7.Remove ignitor screw with a 1/4" nut driver for models using ignitor HA1000 or 5/16" nut driver for models using 102548-08 ignitor. Carefully remove ignitor from nozzle adapter bracket.

Figure 20 - Disconnecting Ignitor Wires CAUTION: Do not bend or strike ignitor element. Handle with care.

8.Carefully remove replacement ignitor from packing.

9.Carefully guide ignitor into opening in nozzle adapter bracket. Do not strike ignitor element. Attach ignitor to nozzle adapter bracket with screw using a 1/4" nut driver for models us- ing ignitor HA1000 or 5/16" nut driver for models using 102548-08 ignitor (see Figure 23). Torque .90 to 1.69 N-m (8 to 15 in-lbs) Do not over torque.

10.Replace combustion chamber.

11.Route the ignitor wires back down through the hole in the lower shell. Connect wires to the ignition control assembly (see Figure 20).

12.Replace side cover (see Figures 18 or 19, page 10).

13.Connect and route fuel line hose and air line hose to nozzle adapter assembly. See Fuel and Air Line Replacement and Proper Routing, page 14.

14.Replace photocell in photocell bracket. Route wires as shown in either (see Figures 23, 24 or 27, page 12).

15.Replace fan (see page 9).

16.Replace fan guard and upper shell (see page 9).

Combustion

Nozzle

Adapter

Chamber

Bracket

 

Air Line

Ignitor

Hose

 

Fuel

 

Line

Ignitor

Hose

Wire

 

Photocell

 

Bracket

Ignition

 

Photocell

Control

Assembly

Assembly

Side Cover

Figure 20 - Disconnecting Ignitor Wires

from Ignition Control Assembly

Ignitor Screw/

Washer Assembly

Ignitor

Ignitor

Nozzle

Element

Photocell

Adapter

Bracket

Bracket

Combustion

ChamberNozzle Adapter

Bracket Opening

Figure 21 - Ignitor HA1000 Replacement

 

Ignitor

Ignitor Element

 

Photocell

Nozzle

Adapter

Bracket

Bracket

Nozzle Adapter

Combustion

Bracket Opening

Chamber

Figure 22 - Ignitor 102548-08 Replacement