Desa BTU/HR owner manual Troubleshooting, Continued, Fault Condition, Possible Cause, Remedy

Models: BTU/HR

1 32
Download 32 pages 60.98 Kb
Page 8
Image 8
See Pump Pressure Adjust-

TROUBLESHOOTING

Continued

FAULT CONDITION

POSSIBLE CAUSE

REMEDY

Motor starts and runs but heater

1. No fuel in tank

1.

Fill tank with kerosene

does not ignite

2.

Pump pressure incorrect

2.

See Pump Pressure Adjust-

 

 

 

 

ment, page 10

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 10

 

4.

Obstruction in nozzle

4.

See Nozzle Assembly, page 13

 

5.

Water in fuel tank

5.

Drain and flush fuel tank with

 

 

 

 

clean kerosene. See Storing,

 

 

 

 

Transporting, or Shipping,

 

 

 

 

page 6

See Fuel Filter, page 10Transporting, or Shipping, WARNING: High voltage!

6.Bad electrical connection be- tween ignitor and ignition con- trol assembly

7.Defective ignitor

8.Defective ignition control as- sembly

9.200 Model Only: Defective fuel valve (Models equipped with fuel valve only)

6.Check electrical connections. See Wiring Diagrams, page 16

7.Replace ignitor, see page 11

8.Replace ignition control as- sembly

9.See Fuel Valve, page 11

Heater ignites but ignition con-

1. Pump pressure incorrect

1.

See Pump Pressure Adjust-

trol assembly shuts heater off

 

 

 

ment, page 10

after a short period of time

2. Dirty air intake, air output,

2.

See Air Output, Air Intake, and

 

 

and/or lint filter

 

Lint Filters, page 9

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 10

 

4.

Obstruction in nozzle

4.

See Nozzle Assembly, page 13

 

5. Photocell assembly not properly

5.

Make sure photocell boot is

 

 

installed (not seeing the flame)

 

properly seated in bracket

 

6.

Dirty photocell lens

6.

Clean photocell lens

Manual backgroundManual background WARNING: High voltage!

7.Bad electrical connection be- tween photocell and ignition control assembly

8.Defective photocell

9.Defective ignition control as- sembly

7.Check electrical connections. See Wiring Diagrams, page 16

8.Replace photocell

9.Replace ignition control as- sembly

8

www.desatech.com

113282-01C

Page 8
Image 8
Desa BTU/HR owner manual Troubleshooting, Continued, Fault Condition, Possible Cause, Remedy, See Pump Pressure Adjust