Desa BTU/HR Operation With Portable Generator, Storing Transporting, Or Shipping, Continued

Models: BTU/HR

1 32
Download 32 pages 60.98 Kb
Page 6
Image 6
TO RESTART HEATER

OPERATION

Continued

TO RESTART HEATER

Wthout ON/OFF Switch

1.Unplug extension cord from outlet and wait 10 seconds. (Wait two minutes if heater has been running.)

2.Repeat steps under To Start Heater.

With ON/OFF Switch

1.Push ON/OFF switch to OFF (O) position and wait 10 seconds (2 minutes if heater has been running).

2.Repeat steps under To Start Heater, page 5.

ON/OFF

Switch with

Light

Figure 7 - ON/OFF Switch, 50/55/60/70 Models

ON/OFF

Switch with

Light

Figure 8 - ON/OFF Switch, 110/115/155/

165/200 Models

OPERATION WITH

PORTABLE GENERATOR

Figure 8 - ON/OFF Switch, 110/115/155/ WARNING: Before operating heater or any appliance from a portable generator, verify that generatorhasbeen properlycon- nected to earth ground. Improper grounding or failure to ground generator can result in electro- cution if a ground fault occurs. Refertoowner’smanualsupplied by generator manufacturer for proper grounding procedures.

The operating voltage range of the heater is 108 to 132 Volts (120 Volts +/- 10%). Prior to plug- ging heater into generator the output voltage should be verified (if generator is equipped with the automatic idle feature, the output voltage should be measured with the generator running at full speed). If the voltage does not measure in this range the heater should not be plugged into the generator.

Refer to Operation, page 5, for starting, stopping, and resetting heater procedures.

Alternator

Ground Lug

Copper or

Brass

Grounding

Point

Ground Wire (#10

AWG - Stranded-

Copper)

Figure 9 - Typical Generator Grounding Method (Generator construction may vary from that shown)

STORING,

TRANSPORTING, OR

SHIPPING

Note: If shipping, transport companies require fuel tanks to be empty.

1.Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed.

2.Replace drain plug if provided.

3.If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters during future use.

4.Replace fuel cap or drain plug. Properly dis- pose of old and dirty fuel. Check with local automotive service stations that recycle oil.

5.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store kerosene over sum- mer months for use during next heating season. Using old fuel could damage heater.

6

www.desatech.com

113282-01C

Page 6
Image 6
Desa BTU/HR owner manual Operation With Portable Generator, Storing Transporting, Or Shipping, Continued, To Restart Heater