ASSEMBLY
(FOR 110/115/155/165/200 MODELS ONLY)
These models are furnished with wheels and a handle. Some models are furnished with a second handle also. Wheels, handle(s), and the mounting hardware are found in the shipping carton.
Tools Needed
•Medium Phillips Screwdriver
•3/8" Open or Adjustable Wrench
•Hammer
1.Slide axle through wheel support frame. Install wheel spacers if provided. Install wheels on axle. IMPORTANT: When installing wheels, point extended hub of wheels toward wheel support frame (see Figure 6).
2.Place cap nuts on axle ends. Gently tap with hammer to secure.
3.Place heater on wheel support frame. Line up holes on fuel tank flange with holes on wheel support frame.
4.Place handle(s) on top of fuel tank flange. In- sert screws through handle(s), fuel tank flange, and wheel support frame. Attach nut finger tight after each screw is inserted.
5.After all screws are inserted, tighten nuts firmly.
Cord Cleat with Bolts and Nuts (If Provided - Set of Two for Right or Left Side)
Screw | Handle | |
| ||
Hot Air | Air | |
Outlet | ||
Inlet | ||
| ||
Fuel |
| |
Tank |
| |
Flange |
| |
Wheel Support |
| |
Frame |
| |
Nut |
| |
| Extended | |
| Axle Hub | |
Cap Nut | Wheel Spacer | |
(If Provided) | ||
Wheel |
Figure 6 - Wheel and Handle Assembly,
110/115/155/165/200 Models Only
OPERATION
IMPORTANT: Review and under- stand the warnings in the Safety Information section, page 2. They are needed to safely oper- ate this heater. Follow all local ordinances and codes when using this heater.
TO START HEATER
1.Follow all ventilation and safety information.
2.Locate heater to provide maximum circulation of the heated air. Follow all location require- ments noted in Safety Information, page 2.
3.Fill fuel tank with kerosene, #1#2 diesel/fuel oil, JET A or
4.Attach fuel cap.
5.For thermostat models, turn thermostat knob clockwise to the high position.
6.Plug heater’s power cord into approved, grounded,
Extension Cord Size Requirement
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm2) rated cord
11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm2) rated cord
101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm2) rated cord
7.Plug extension cord into standard 120 volt/60 hertz,
Note: For heater without ON/OFF switch, ig- nitor will preheat for five seconds, then heater will start.
Note: For heater with ON/OFF switch, push switch to ON() position and heater should start in 5 seconds. If heater does not start, see Troubleshooting, page 7.
8.For thermostat models, adjust thermostat knob to the desired setting. Note: A cold heater may affect the thermostat setting. This thermostat is a
TO STOP HEATER
Without ON/OFF Switch
Unplug extension cord from outlet.
With ON/OFF Switch
Push ON/OFF switch to OFF (O) position. Un- plug heater when not in use.
www.desatech.com | 5 |