SERVICE PROCEDURES
Continued
IGNITION CONTROL ASSEMBLY
WARNING: High voltage!
1.Unplug heater.
2.Remove side cover screws (4) using 5/16" nut- driver to expose ignition control assembly.
3.Remove fuse cover (see Figure 34).
4.Remove fuse from fuse clips (see Figure 34).
5.Replace fuse with fuse of the same type and rating
6.Replace fuse cover (see Figure 34).
7.Replace side cover (see Figures 18 or 19, page 10).
Fuse Clips | Fuse |
| |
| Cover |
| Fuse |
Figure 34 - Replacing Fuse
SPECIFICATIONS
Model Size | 40 | 50/55/60 | 70 | 110/115 | 155 | 165 | 200 |
Output Rating (Btu/Hr) | 40,000 | 50/55/ | 70,000 | 110,000 | 155,000 | 165,000 | 200,000 |
|
| & 60,000 |
| & 115,000 |
|
|
|
Fuel | Use only kerosene, #1/#2 diesel/fuel oil, JET A or |
| |||||
Fuel Tank Capacity |
|
|
|
|
|
|
|
(U.S. Gal./Liters) | 3/11.3 | 5/18.9 | 5/18.9 | 9/34 | 13.5/51 | 13.5/51 | 13.5/51 |
Fuel Consumption |
|
|
|
|
|
|
|
(Gal. Per Hr/Liters Per Hr) | .3/1.14 | .44/1.67 | .52/1.97 .85/3.00 | 1.14/4.31 1.2/4.54 | 1.4/5.3 | ||
Pump Pressure (psi) | 3.0 | 3.4 | 4.7 | 5.1 | 5.2 | 5.6 | 6.2 |
Electric Requirements | 120 V/60 HZ (Same All Models) |
|
|
| |||
Amperage (Normal Run) | 2.0 | 2.0 | 2.8 | 3.6 | 3.6 | 3.6 | 3.6 |
Motor RPM | 1725 | 1725 | 3440 | 3400 | 3400 | 3400 | 3400 |
Hot Air Output (CFM) | 170 | 180 | 360 | 490 | 550 | 575 | 600 |
Motor HP | 1/15 | 1/15 | 1/8 | 1/5 | 1/5 | 1/5 | 1/4 |
Shipping Weight | 32/14.5 | 34/15.4 | 36/16.3 | 56/25.4 | 69/31.3 | 71/32.2 | 83/37.6 |
(Approximate Pounds/Kilograms) |
|
|
|
|
|
| |
Heater Weight without Fuel | 28/12.7 | 30/13.6 | 32/14.5 | 48/21.8 | 60/27.2 | 61/27.7 | 72/32.7 |
(Approximate Pounds/Kilograms) |
|
|
|
|
|
|
*Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter maintenance. Use in extreme cold temperatures may require nontoxic
www.desatech.com | 15 |