Figure 34 - Replacing FuseSPECIFICATIONSWARNING: High voltage!

1.Unplug heater.

2.Remove side cover screws (4) using 5/16" nut- driver to expose ignition control assembly.

3.Remove fuse cover (see Figure 34).

4.Remove fuse from fuse clips (see Figure 34).

5.Replace fuse with fuse of the same type and rating (GMA-10). Do not substitute a fuse with a higher current rating.

6.Replace fuse cover (see Figure 34).

7.Replace side cover (see Figures 18 or 19, page 10).

Fuse Clips

Fuse

 

 

Cover

 

Fuse

Figure 34 - Replacing Fuse

SPECIFICATIONS

Model Size

40

50/55/60

70

110/115

155

165

200

Output Rating (Btu/Hr)

40,000

50/55/

70,000

110,000

155,000

165,000

200,000

 

 

& 60,000

 

& 115,000

 

 

 

Fuel

Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels*

 

Fuel Tank Capacity

 

 

 

 

 

 

 

(U.S. Gal./Liters)

3/11.3

5/18.9

5/18.9

9/34

13.5/51

13.5/51

13.5/51

Fuel Consumption

 

 

 

 

 

 

 

(Gal. Per Hr/Liters Per Hr)

.3/1.14

.44/1.67

.52/1.97 .85/3.00

1.14/4.31 1.2/4.54

1.4/5.3

Pump Pressure (psi)

3.0

3.4

4.7

5.1

5.2

5.6

6.2

Electric Requirements

120 V/60 HZ (Same All Models)

 

 

 

Amperage (Normal Run)

2.0

2.0

2.8

3.6

3.6

3.6

3.6

Motor RPM

1725

1725

3440

3400

3400

3400

3400

Hot Air Output (CFM)

170

180

360

490

550

575

600

Motor HP

1/15

1/15

1/8

1/5

1/5

1/5

1/4

Shipping Weight

32/14.5

34/15.4

36/16.3

56/25.4

69/31.3

71/32.2

83/37.6

(Approximate Pounds/Kilograms)

 

 

 

 

 

 

Heater Weight without Fuel

28/12.7

30/13.6

32/14.5

48/21.8

60/27.2

61/27.7

72/32.7

(Approximate Pounds/Kilograms)

 

 

 

 

 

 

*Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter maintenance. Use in extreme cold temperatures may require nontoxic anti-icer additives.