Sanyo SAP-KRV94EHDX service manual Remote Control Unit

Page 67

Remote Control Unit

Transmitter Sensor

Display

 

 

 

NIGHT

 

 

 

 

 

 

SETBACK

 

 

 

 

LED

 

button

 

 

 

ION

CLEAN

 

 

 

 

 

button

button

 

 

 

MODE selector

 

ON/OFF operation

 

 

 

 

 

button

 

QUIET

button

 

FAN SPEED

 

 

 

 

FLAP button

button

HIGH POWER

selector button

 

 

CANCEL button

 

button

SENSOR button

 

 

 

CHILD LOCK button

 

 

 

 

1.2.3.5HR. ON TIME

Advance

 

 

 

Advance

OFF TIME

 

TIMER

setting

 

 

 

 

 

 

 

setting

 

button

buttons

Return

 

Return

 

 

buttons

 

Temperature

 

 

 

 

 

 

 

 

TIMER selector

 

setting button

 

 

 

 

 

 

 

button

 

 

 

 

 

 

 

 

 

 

CLOCK

Time

Temperature

 

 

 

button

display

display

 

 

(Cover closed)

 

 

selector

selector button

 

 

 

 

button

 

 

(Cover opened)

<Cover closed>

Transmitter When you press the buttons on the remote control unit, the mark appears in the display to transmit the setting changes to the receiver in the air conditioner.

Sensor

A temperature sensor inside the remote control unit senses the room temperature.

 

 

Display

Information on the operating conditions is displayed while the remote control

 

unit is switched on. If the unit is turned off, FLAP setting and FAN SPEED

 

setting are not displayed.

 

 

ION button

: This button is for turning the negative ions generated during

 

operation on and off.

 

 

ON/OFF operation button

This button is for turning the air conditioner on and off.

 

 

1.2.3.5HR. TIMER button

: When you press this button, regardless of whether the unit is on or off,

(1.2.3.5-HOUR OFF TIMER)

the unit operates for 1, 2, 3 or 5 hours and then shuts down.

 

 

LED CLEAN button

: If this button is pressed during AUTO, HEAT, DRY, COOL or FAN

 

operation, the UV anti-bacterial unit is activated for one hour and

 

cleans the air blown from the air conditioner.

 

 

HIGH POWER button

: If this button is pressed during HEAT, DRY, COOL or FAN operation,

 

the unit operates at maximum output for 30 minutes, regardless of the

 

desired temperature.

 

The fan speed is 1step above ‘‘HIGH’’.

Temperature setting buttons Press the button to increase the set temperature. (TEMP.) Press the button to reduce the set temperature.

For details, see Automatic operation and Manual operation.

QUIET button

: When you press this button, the fan rotates slower than the fan

 

speed setting to provide a quieter operating sound.

8

OI-791-8-EG

 

Image 67
Contents DC Inverter Split System AIR Conditioner Table of Contents Checking Electrical Components Please Read Before Starting For safe installation and trouble-free operation, you MustOperating Range Indoor Unit SAP-KRV94EHDX Unit SpecificationsOutdoor Unit SAP-CRV124EHDX SAP-KRV124EHDXSAP-KRV94EHDX Major Component SpecificationsCB-KRV124EHDX Outdoor Unit CB-CRV124EHDX Other Component Specifications Dimensional Data Dia .35 1/4 Indoor Unit SAP-KRV94EHDX Outdoor Unit SAP-CRV94EHDX Refrigerant Flow DiagramRefrigerant Flow Diagram Insulation of Refrigerant TubingPerformance Data Temperature ChartsIndoor Unit SAP-KRV124EHDX Outdoor Unit SAP-CRV124EHDX Air Throw Distance Charts Indoor Unit SAP-KRV124EHDX Cooling Electrical CharacteristicsHeating Outdoor Unit Indoor Unit Electric Wiring DiagramsSAP-CRV94EHDX SAP-KRV94EHDX SAP-CRV124EHDX SAP-KRV124EHDX Installation Site Selection About Wiring System Diagram Recommended Wire Length and DiameterMounting on a Wall Remote Control Unit Installation PositionON/OFF How to Test Run the Air ConditionerHow to remove the grille Remove the Grille to Install the Indoor UnitHow to replace the grille Address Setting of the Remote Control Unit MaintenanceSwitching the remote controller address Removing and Mounting the Drain Hose Removing the Electrical Component Box Page Removing the Panel Motor Removing the Drain Pan Air Outlet Assy Removing and Mounting the Drain Pan Air Outlet AssyWater in the drain pan Mounting the Drain Pan Air Outlet AssyRemoving the Negative Ion Generator Removing the Fan Motor Removing and Mounting the Fan MotorMounting the Fan Motor Removing the Fan How to Connect How to DisconnectAuto cooling/heating operation FunctionsOperation Functions Emergency operationLamp colors Timer backupFreeze prevention Compressor discharge temperature controlProtective Functions Overload prevention during heatingMode Heating Mode CoolingNon-Stop Defrosting Precautions before Performing Inspection or Repair TroubleshootingMethod of Self-Diagnostics ION Timer Operation Self-diagnostics LampsChecking the Indoor and Outdoor Units Trouble Diagnosis of Indoor and Outdoor Fan Motor Diagnostic procedureDiagnostic results Remedy for symptom 3 toOutdoor Fan Motor Noise malfunction Noise Malfunction and Electromagnetic InterferenceElectromagnetic interference Upper right screw Grille Screw Flap Screw cover Making a Diagnosis of the Panel Motor Measurement of Insulation Resistance Checking Electrical ComponentsChecking Continuity of Fuse on PCB Assy Size of flare Refrigerant R410A Special Precautions When Servicing UnitCharacteristics of New Refrigerant R410A Checklist before ServicingIf refrigerant R410A is exposed to fire Tubing precautionsNo addition of compressor oil for R410A No use of refrigerant other than R410ATool Distinction Tool Name Tubing Installation ProceduresTools Specifically for R410A For servicing, use the following tools for R410ACase of Compressor Malfunction Procedure for Replacing CompressorUnit. This may cause Configuration and characteristics of cylindersRecharging Never charge a large amountWelding leaking points Case Refrigerant is LeakingUse of Existing Units When Tubes are ExtendedCharging Additional Refrigerant Retro-Fitting Existing SystemsOI-852-6-4180-791-00-0 Child Lock FeaturesAlert Symbols ContentsProduct Information Safety Instructions Installation LocationElectrical Requirements Names of Parts Unit Display and Operation Button Remote Control Unit Display Remote Control Unit Cool AutoHeat DRYONE TIME/EVERYDAY Using the Remote Control UnitRemote control unit mount Mounting screws 4 x 16 included Using the Remote Control UnitControl Unit Press the ON/OFF operation button Operation with the Remote Control UnitStep StepCover closed Cover opened Step Operation with the Remote Control UnitAdjusting the Fan Speed Setting Temperature Cooling and DRY ModeNight Setback Mode is used for saving energy SettingQuiet Mode Special Remarks Example To set to Setting the TimerOperation Indication OFF Setting the TimerTo cancel a timer program Press the Cancel button 2230 610 2000 Present timeOperation together with the Daily ON/OFF Repeat Timer Using the 1.2.3.5-Hour OFF TimerSetting procedure Cancellation procedureSweep Adjusting the Airflow DirectionFAN Heat Indoor Unit Care and CleaningFilter Care and CleaningHow to replace the anti-mold Remounting the front panelNegative ion generator metal electrodes inside plastic case How to clean the air clean filterOperating Range TroubleshootingTrouble Possible Cause Remedy Osaka, Japan Sept

SAP-KRV94EHDX specifications

The Sanyo SAP-KRV94EHDX is a cutting-edge split-type air conditioning unit that exemplifies advanced technology and efficiency. Designed for both residential and commercial spaces, this model is equipped with features that cater to various cooling and heating needs.

One of the main highlights of the Sanyo SAP-KRV94EHDX is its energy efficiency. With a high Energy Efficiency Ratio (EER), this unit minimizes energy consumption while maximizing cooling performance. This not only results in lower electricity bills but also contributes to a reduced carbon footprint, making it an environmentally friendly choice for users.

The SAP-KRV94EHDX employs inverter technology, which allows the compressor to adjust its speed dynamically based on the temperature requirements of the environment. This means that the unit operates more quietly and uses less energy when maintaining a consistent temperature. The inverter system ensures that the air conditioner can quickly reach the desired cooling or heating temperature and maintain it without the frequent on-off cycles typical of traditional units.

Additionally, the air conditioning unit comes with a powerful cooling capacity, effectively managing larger spaces. It can easily handle varying ambient conditions while providing rapid cooling in extremely warm weather, making it perfect for areas with hot climates.

Other notable features include a user-friendly remote control, allowing users to adjust settings from a distance effortlessly. The unit also incorporates a multi-stage air filtration system designed to remove dust, allergens, and other airborne particles, contributing to better indoor air quality.

The Sanyo SAP-KRV94EHDX is not just about functionality; it also boasts a sleek and modern design that blends seamlessly with various interior aesthetics. Its quiet operation ensures that it does not disturb daily activities, making it suitable for bedrooms, offices, and living spaces.

Moreover, the unit comes with various operational modes, including cooling, dehumidification, and a heating function. This versatility makes the SAP-KRV94EHDX an all-season solution for climate control.

In summary, the Sanyo SAP-KRV94EHDX is a top-tier air conditioning unit that combines efficiency, advanced technology, and user convenience. Its inverter technology, multi-stage air filtration, and modern design make it a reliable choice for anyone seeking comfort throughout the year.