Sanyo SAP-KRV94EHDX service manual Using the Remote Control Unit, One Time/Everyday

Page 69

Remote Control Unit (continued)

SENSOR button

When you press this button (use a small-tipped object such as a ballpoint

 

 

 

pen), the

mark will appear at the display. And the room temperature is

 

 

 

detected by the sensor which is built into the indoor unit and the air

 

 

 

conditioner is controlled accordingly.

 

 

 

If the remote control is located near a heat source, such as a space heater or

 

NOTE

 

 

 

 

in direct sunlight, press the SENSOR button to switch to the sensor on the

 

 

 

 

 

 

indoor unit.

 

 

 

 

 

Temperature Display Selector

This switches the temperature display between °C and °F.

 

button

 

 

 

 

 

 

Time Display Selector button

This switches the time display between 24-hour time and 12-hour time.

 

 

 

 

TIMER Selector button

This button switches ONE TIME or EVERYDAY. When you select

(ONE TIME/EVERYDAY)

EVERYDAY,

is displayed and continuously operates this function

 

 

 

everyday. The initial setting is EVERYDAY. If you select ONE TIME, it

 

 

 

operates until setting time of timer.

 

 

 

 

CANCEL button

If you want to cancel the setting time of ON or OFF, press the ON or OFF button

 

 

 

first, then press the CANCEL button. The CANCEL function is invalid for the

 

 

 

1.2.3.5HR. TIMER.

 

 

 

 

CLOCK button

The CLOCK button is used to set the present time. Press the CLOCK button

 

 

 

first, then select the advance or return keys on the ON or OFF TIME setting

 

 

 

button. Press the CLOCK button again to set adjusted present time.

 

 

 

 

CHILD LOCK button

The CHILD LOCK button is used to tamperproof and protect the unit from

 

 

 

being incorrectly operated. The setting or canceling this function is effected

 

 

 

by pressing the button for at least two seconds.The initial setting is set to

 

 

 

CHILD LOCK off.

 

 

 

: CHILD LOCK on.

 

 

All key access functions are invalid while the CHILD LOCK function is on.

 

NOTE

 

 

 

 

 

 

 

 

 

 

ADDRESS switch

• The ADDRESS switch changes to prevent mixing of signals from remote

 

 

 

control units when two air conditioners are installed next to each other.

 

 

 

The ADDRESS switch is located inside of rear cover on the remote

 

 

 

control unit, and is set to A. For more information, please contact the

 

 

 

dealer where you made the purchase.

 

 

 

• Normally, tab on the remote control unit should not be bent.

 

 

 

 

 

NOTE

The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.

Using the Remote Control Unit

How to Install Batteries

1. Slide the cover in the direction indicated by the arrow and remove it.

2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment.

10

OI-791-10-EG

 

Image 69
Contents DC Inverter Split System AIR Conditioner Table of Contents Checking Electrical Components Please Read Before Starting For safe installation and trouble-free operation, you MustOperating Range Indoor Unit SAP-KRV94EHDX Unit SpecificationsOutdoor Unit SAP-CRV124EHDX SAP-KRV124EHDXSAP-KRV94EHDX Major Component SpecificationsCB-KRV124EHDX Outdoor Unit CB-CRV124EHDX Other Component Specifications Dimensional Data Dia .35 1/4 Refrigerant Flow Diagram Refrigerant Flow DiagramInsulation of Refrigerant Tubing Indoor Unit SAP-KRV94EHDX Outdoor Unit SAP-CRV94EHDXPerformance Data Temperature ChartsIndoor Unit SAP-KRV124EHDX Outdoor Unit SAP-CRV124EHDX Air Throw Distance Charts Indoor Unit SAP-KRV124EHDX Electrical Characteristics CoolingHeating Electric Wiring Diagrams Outdoor Unit Indoor UnitSAP-CRV94EHDX SAP-KRV94EHDX SAP-CRV124EHDX SAP-KRV124EHDX Installation Site Selection About Wiring System Diagram Recommended Wire Length and DiameterMounting on a Wall Remote Control Unit Installation PositionON/OFF How to Test Run the Air ConditionerRemove the Grille to Install the Indoor Unit How to remove the grilleHow to replace the grille Maintenance Address Setting of the Remote Control UnitSwitching the remote controller address Removing and Mounting the Drain Hose Removing the Electrical Component Box Page Removing the Panel Motor Removing the Drain Pan Air Outlet Assy Removing and Mounting the Drain Pan Air Outlet AssyWater in the drain pan Mounting the Drain Pan Air Outlet AssyRemoving the Negative Ion Generator Removing and Mounting the Fan Motor Removing the Fan MotorMounting the Fan Motor Removing the Fan How to Connect How to DisconnectOperation Functions FunctionsEmergency operation Auto cooling/heating operationLamp colors Timer backupProtective Functions Compressor discharge temperature controlOverload prevention during heating Freeze preventionMode Cooling Mode HeatingNon-Stop Defrosting Troubleshooting Precautions before Performing Inspection or RepairMethod of Self-Diagnostics ION Timer Operation Self-diagnostics LampsChecking the Indoor and Outdoor Units Diagnostic results Diagnostic procedureRemedy for symptom 3 to Trouble Diagnosis of Indoor and Outdoor Fan MotorOutdoor Fan Motor Noise Malfunction and Electromagnetic Interference Noise malfunctionElectromagnetic interference Upper right screw Grille Screw Flap Screw cover Making a Diagnosis of the Panel Motor Measurement of Insulation Resistance Checking Electrical ComponentsChecking Continuity of Fuse on PCB Assy Characteristics of New Refrigerant R410A Refrigerant R410A Special Precautions When Servicing UnitChecklist before Servicing Size of flareNo addition of compressor oil for R410A Tubing precautionsNo use of refrigerant other than R410A If refrigerant R410A is exposed to fireTools Specifically for R410A Tubing Installation ProceduresFor servicing, use the following tools for R410A Tool Distinction Tool NameCase of Compressor Malfunction Procedure for Replacing CompressorRecharging Configuration and characteristics of cylindersNever charge a large amount Unit. This may causeWelding leaking points Case Refrigerant is LeakingCharging Additional Refrigerant When Tubes are ExtendedRetro-Fitting Existing Systems Use of Existing UnitsOI-852-6-4180-791-00-0 Child Lock FeaturesContents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Unit Display and Operation Button Remote Control Unit Display Remote Control Unit Heat AutoDRY CoolONE TIME/EVERYDAY Using the Remote Control UnitUsing the Remote Control Unit Remote control unit mount Mounting screws 4 x 16 includedControl Unit Step Operation with the Remote Control UnitStep Press the ON/OFF operation buttonCover closed Cover opened Step Operation with the Remote Control UnitAdjusting the Fan Speed Night Setback Mode is used for saving energy Cooling and DRY ModeSetting Setting TemperatureQuiet Mode Special Remarks Setting the Timer Example To set toOperation Indication To cancel a timer program Press the Cancel button Setting the Timer2230 610 2000 Present time OFFSetting procedure Using the 1.2.3.5-Hour OFF TimerCancellation procedure Operation together with the Daily ON/OFF Repeat TimerAdjusting the Airflow Direction SweepFAN Heat Indoor Unit Care and CleaningHow to replace the anti-mold Care and CleaningRemounting the front panel FilterNegative ion generator metal electrodes inside plastic case How to clean the air clean filterTroubleshooting Operating RangeTrouble Possible Cause Remedy Osaka, Japan Sept

SAP-KRV94EHDX specifications

The Sanyo SAP-KRV94EHDX is a cutting-edge split-type air conditioning unit that exemplifies advanced technology and efficiency. Designed for both residential and commercial spaces, this model is equipped with features that cater to various cooling and heating needs.

One of the main highlights of the Sanyo SAP-KRV94EHDX is its energy efficiency. With a high Energy Efficiency Ratio (EER), this unit minimizes energy consumption while maximizing cooling performance. This not only results in lower electricity bills but also contributes to a reduced carbon footprint, making it an environmentally friendly choice for users.

The SAP-KRV94EHDX employs inverter technology, which allows the compressor to adjust its speed dynamically based on the temperature requirements of the environment. This means that the unit operates more quietly and uses less energy when maintaining a consistent temperature. The inverter system ensures that the air conditioner can quickly reach the desired cooling or heating temperature and maintain it without the frequent on-off cycles typical of traditional units.

Additionally, the air conditioning unit comes with a powerful cooling capacity, effectively managing larger spaces. It can easily handle varying ambient conditions while providing rapid cooling in extremely warm weather, making it perfect for areas with hot climates.

Other notable features include a user-friendly remote control, allowing users to adjust settings from a distance effortlessly. The unit also incorporates a multi-stage air filtration system designed to remove dust, allergens, and other airborne particles, contributing to better indoor air quality.

The Sanyo SAP-KRV94EHDX is not just about functionality; it also boasts a sleek and modern design that blends seamlessly with various interior aesthetics. Its quiet operation ensures that it does not disturb daily activities, making it suitable for bedrooms, offices, and living spaces.

Moreover, the unit comes with various operational modes, including cooling, dehumidification, and a heating function. This versatility makes the SAP-KRV94EHDX an all-season solution for climate control.

In summary, the Sanyo SAP-KRV94EHDX is a top-tier air conditioning unit that combines efficiency, advanced technology, and user convenience. Its inverter technology, multi-stage air filtration, and modern design make it a reliable choice for anyone seeking comfort throughout the year.