6. REFRIGERANT FLOW DIAGRAM
Indoor Unit: XS1852 | Outdoor Unit: C1852, CL1852 |
Indoor Unit
Evaporator |
Outdoor Unit
| Wide tube |
|
Wide tube | service valve | Accumulator |
O. D. |
| Compressor |
5/8" |
| |
(15.88 mm) |
| |
|
| |
| Narrow tube | Condenser |
| Capillary | |
Narrow tube | service valve | tube |
O. D. |
|
|
1/4" |
|
|
(6.35 mm) |
|
|
|
| 1898_C_I |
Insulation of Refrigerant Tubing
IMPORTANT
To prevent heat loss and wet floors due to dripping
of condensation, both the wide and narrow tubes must be well insulated with a proper insulation
material. The thickness of the insulation should be a min. 5/16 in.
After a tube has been CAUTION insulated, never try to bend it
into a narrow curve because it can casue the tube to break or crack.
Thickness:
Min. 5/16 in.
Wide tube
Insulation
Thickness:
Min. 5/16 in.
Narrow tube
0999_C_I
SM830079
– 16 –