2. SPECIFICATIONS

(2)Major Component Specifications

(A)Indoor Unit

 

MODEL No.

 

 

 

 

 

XS1852

 

 

 

 

 

 

 

 

 

 

 

 

 

Source

 

 

 

 

230 - 208 V / 1 phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote controller (Accessory)

 

 

 

 

 

RCS - 5PS4U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller P. C. B Ass'y

 

 

 

 

 

CR - TS2432

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control circuit fuse

 

 

 

 

 

250 V, 3 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Ass'y

 

 

 

 

 

SW - X363GS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan (Number … diameter)

in.

(mm)

 

 

Turbo (1…19-9/32 (490))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

 

 

 

SFG6X - 41A5P

 

 

 

 

 

 

 

 

 

 

 

 

 

Source

 

 

 

 

230 - 208 V / 1 phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of pole … r.p.m. (230 V, High)

 

rpm

 

 

 

6 … 451

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal output

 

W

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance

 

Ω

BRW -

WHT

:

114.0

,

ORG -

YEL

:

66.4

 

(Ambient temperature 68 °F)

 

 

WHT -

VLT

:

23.9

,

WHT -

PNK

:

77.4

 

 

 

 

 

VLT -

ORG

:

12.4

,

YEL -

BLK

:

82.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating temperature

Open

°F

 

 

 

266

±

14.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Close

°F

 

 

 

174.2

±

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Run capacitor

VAC,

μF

 

 

 

440 V , 3.5 μF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil

 

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rows … Fins per inch

 

 

 

 

 

2 … 14.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Face area

ft.2

(m2)

 

 

 

3.2 (0.297)

 

 

 

 

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model No.

 

 

 

 

 

PNR - XS2432

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicator Lamp Ass'y

 

 

 

 

 

IND - XS2432

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto louver motor

 

 

 

 

 

MT8 - 3C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto louver motor … Rated

V, W,

rpm

 

 

 

240 VAC , 3 W , 3 rpm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance (Ambient temperature 77 °F)

 

Ω

 

 

 

16,430 Ω ± 8 %

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

SM830079

– 8 –

Image 8
Contents Technical Data Indoor Unit Outdoor Unit XS1852 C1852Please Read Before Starting If Necessary, Get HelpTable of Contents Introduction Read Me First XS1852 / CL1852 Operating Range XS1852 / C1852 Specifications Unit SpecificationsData Subject to Change Without Notice Major Component Specifications Indoor Unit Fan motorMajor Component Specifications Outdoor Unit CompressorOther Component Specifications Indoor Unit Model No XS1852 Power TransformerOther Component Specifications Outdoor Unit Model No CL1852Dimensional Data Indoor Unit XS1852Outdoor Unit C1852, CL1852 Performance Charts 230VAIR Throw Distance Chart Model XS1852To prevent heat loss and wet floors due to dripping Refrigerant Flow DiagramInsulation of Refrigerant Tubing Installation Instructions Tubing LengthSelecting the Installation Site AvoidBaffle Plates for the Outdoor Unit CL×× models only ÃInstall the outdoor unitChoose a place that is well ventilated Electrical Wiring General Precautions on Wiring Wiring System Diagram ModelsElectrical Data Electric Wiring Diagram Electrical Wiring DiagramsSchematic Diagram Outdoor Unit C1852 Outdoor Unit CL1852 Room Temperature Control Processes and FunctionsFreeze Prevention Drain Pump ControlMedium Service Procedures 1334XS Check remote control unit There is a possibility of short circuitCheck. auxiliary relay Check Operation selector switch in the indoor unitTransformer in indoor unit Check fuse on the P.C.B. Ass’y in the indoor unit FMIOutdoor Unit does not Run Check Cool / FAN selector switch in the remote control unitCheck set temperature Check float switch Refer to 11 Drain Pump Control Check compressor motor magnetic contactorIndoor Unit does not Run Indoor fan and louver motor do not runSome Part does not Operate Indoor fan does not runCompressor does not Run Outdoor Fan does not RunOutdoor Fan does not Run for CL1852 Poor Cooling Excessive CoolingRoom temp. Sensor in the remote control unit is defective Operation of Major Electrical PartsPower Supply Wires Measurement of Insulation Re- sistance for Electrical partsChecking the Protective Devices Compressor motor thermal protector . . . . . . Outdoor unitIndoor fan motor FMI Indoor unit Measure the coil resistance Motor capacitor Both in indoor and outdoor unitMethod Used to Replace Fuse on PCB Ass’y Thermistor Characteristic CurveContinuity of fuse on P.C.B. Ass’y Central Region