Graco 24R021 Maintenance, Install Restrictors or Plugs, Volume Balancing, Routine Cleaning

Page 11

Install Restrictors or Plugs

Two 0.024 in. restrictors are installed with the gun. An extra 0.032 in. restrictor is included with the gun. If nec- essary, use this restrictor to balance the pressures. Optional restrictors in various sizes are also available. Restrictors create back pressure and make up for vis- cosity differences between A (ISO) and B (RES). See pressure drop chart in FIG. 2 on page 15 and see the Volume Balancing section. See 249765 Restrictor Kit on page 14.

1.Perform Pressure Relief Procedure, page 10.

2.Remove restrictors (E).

3.If using one or more restrictors, assemble o-rings (CC) and screens (BB) onto restrictors (AA). See FIG. 2 on page 15.

4.If using one or more plugs (see Accessories on page 14), assemble o-rings (CC) onto plugs.

5.Screw assembled restrictors or plugs into outlet manifold (F).

NOTICE

Restrictors and plugs can be damaged if they are overtightened. Torque to 40-50 in-lb (4.5-5.6 N•m).

Volume Balancing

Ratio errors can occur between the proportioner and the manifold, even if the proportioner output ratio is very accurate.

Different restrictor sizes are available to correct imbal- ances. See FIG. 2 on page 15 for available sizes.

Check Valve Imbalance

If resin and hardener are at or near 1:1 ratio, when one check valve opens, the resulting surge closes the other. This check valve oscillation causes ratio imbalance.

Install restrictors on both sides to meter a smooth flow to the manifold.

Maintenance

Sizing Restrictors

If resin and hardener are at or near 1:1 ratio and viscos- ities are similar, add a few hundred psi pressure drop to each side to prevent check valve oscillation. Use the chart in FIG. 2 on page 15, or use a restrictor about twice the size of your spray tip, on both sides.

Maintenance

Routine Cleaning

Restrictor Screens

Soak the restrictor screens in solvent regularly to clean. If soaking is ineffective, replace restrictor screens.

Restrictors

Soak the restrictors in solvent and use the included vise (30) and drill bit (31) to clean the orifice.

Check Valves

Soak the check valves in solvent. Use a small screw driver to actuate the check valve ball and spring to remove any restriction. Ensure fluid flows freely through the check valve before re-installing.

Outlet Manifold

Use drill bits to clean the outlet manifold (F) regularly. See the following drill bit size table.

Item

Drill Bit Size

Outlet manifold fluid outlet . . . . . 1/4 in. (6 mm)

Outlet manifold inner passage . . 1/8 in. (3 mm)

(Restrictor size) 0.018 in. . . . . . . #77 (0.45 mm)

0.024 in. . . . . . . . . . . . . . . . . . . . #73 (0.61 mm); included

0.032 in. . . . . . . . . . . . . . . . . . . . #67 (0.81 mm)

0.040 in. . . . . . . . . . . . . . . . . . . . #60 (1.01 mm)

0.062 in. . . . . . . . . . . . . . . . . . . . 1/16 in. (1.59 mm)

0.094 in. . . . . . . . . . . . . . . . . . . . 3/32 in. (2.38 mm)

Drill bit pin vise . . . . . . . . . . . . . . 117661; included

332198C

11

Image 11
Contents 2K Manual Dispense Valve Important Safety InstructionsRelated Manuals ContentsToxic Fluid or Fumes Hazard Equipment Misuse Hazard Important Isocyanate ISO Information Changing Materials Key InstallationPrime Perform Pressure Relief Procedure onInstall Restrictors or Plugs, see OperationDispense Install Disposable Static MixerPerform Pressure Relief Procedure, Ratio CheckingFlushing Pressure Relief Procedure Daily ShutdownRoutine Cleaning MaintenanceInstall Restrictors or Plugs Volume BalancingProblem Cause Solution TroubleshootingPart Description Qty PartsRestrictor Kit AccessoriesRestrictor Diameter and Part No Key Technical DataTypical Restrictor Pressure Drop Pressure Drop in psi MPa, barGraco Information Graco Standard Warranty