Sanyo C2432, CL2432 Refrigerant Tubing, Indoor Unit Tubing Rear-left tubing, Rear-right tubing

Page 14

4. Refrigerant Tubing

4-1. Indoor Unit Tubing

Rear-left tubing

NOTE

For rear-left tubing, optional tube connection (C) (APR- EN46U1B) is necessary. Please consult your nearest sales outlet or A/C workshop.

1.Make a 3-3/16" hole in the wall, centered on the crossing point between the triangle marks (A and B) on the rear panel. (Fig. 30a)

2.Set the rear panel at its original position where it was installed with screws.

3.Cut the wide tube at a point 4-1/8" from the triangle mark.

4.Remove the 1/2" flare nut from the optional tube connection (C), place it on the cut wide tube, and then flare the wide tube. (Fig. 30b)

5.Connect the optional tube connection (C) to the wide tube.

6.Connect the 3/4" tube to the connected optional tube connection.

7.Connect the 3/8" tube to the narrow tube.

8.Cover the narrow and wide tubes with insulation material.

Rear-right tubing

9.Make a 3-3/16" hole in the wall, centered on the crossing point between the triangle marks (A' and B') on the rear panel. (Fig. 30a)

10.Connect the 3/4" tube to the wide tube.

11.Connect the 3/8" tube to the narrow tube.

12.Cover the narrow and wide tubes with insulation material.

4-2. Outdoor Unit Tubing

1.Connect a wide tube (3/4") to the wide tube valve. (Fig. 31a)

2.Connect the tube assy, which was packed in the indoor unit carton, to the narrow tube valve.

3.Before attaching the tube assy to the mounting valve, wrap the supplied packing A (3/4" 1-3/8" T3/16") onto the 5/16" tube of the tube assy to avoid direct contact of the tube assy with the mounting valve. (Fig. 31b, 31c)

2. Mount the rear panel

 

 

 

 

1. Cut hole

B'

B

in wall

A'

A

 

Rear View

Wide tube

3. Cut 4-1/8"

 

4. Flare

5. Connect

Optional tube connection (C) 1/2" (Optional part)

Fig. 30a

3. Cut wide tube

4. Flare wide tube

5. Connect tube

7. Connect

assy

narrow tube

 

3/8"

Optional tube connection (C) 1/2" (Optional part)

6. Connect

Narrow

tube 3/8"

wide tube

 

3/4"

 

Fig. 30b

Narrow tube valve

Wide tube valve

Mounting valve

Packing B

Clamp

Packing A

Tube assy

Narrow tube (3/8")

 

Wide tube (3/4")

Fig. 31a

13

Image 14
Contents Installation Instructions Contents…In Moist or Uneven Locations …In a Ceiling, Wall or Floor…In a Room …In an Area with High WindsGeneral Indoor Unit Installation Site SelectionAdditional Materials Required for Installation Outdoor Unit How to Install the Indoor Unit If Wooden Wall Install the Rear Panel on the WallRemove the Grille to Install the Indoor Unit If Block, Brick, Concrete or Similar Type WallShape the Indoor Side Tubing How to replace the grilleWiring Instructions General precautions on wiring Recommended Wire Length and Diameter AWGWiring Instructions for Inter-unit Connections How to remove the cover plateFor stranded wiring Mounting Right-side tubing If using a stepladder, be carefulHelp when feeding the tubing To keep your balance and notDrain Hose Risk of Electric ShockRear-right tubing Refrigerant TubingIndoor Unit Tubing Rear-left tubing Outdoor Unit TubingTaping the Tubes Connecting Tubing between Indoor and Outdoor UnitsInsulation of Refrigerant Tubing For C2432 and CL2432 Never try to bend it into a narFinishing the Installation When mounting the remote control unit to prevent theft Remote Control Unit Installation PositionWhen using the remote control unit Mounting on a Wall
Related manuals
Manual 48 pages 35.01 Kb

CL2432, C2432 specifications

The Sanyo C2432 and CL2432 are cutting-edge lithium coin cell batteries renowned for their reliability and versatility in a range of electronic applications. These batteries are designed to provide efficient power solutions for devices requiring compact energy sources, making them ideal for medical devices, watches, calculators, and various portable electronics.

One of the main features of the Sanyo C2432 and CL2432 is their high energy density. This capability ensures that these batteries can deliver a significant amount of energy in a small size, extending the operational time of devices without frequent replacements. Typically, the nominal voltage of these batteries is 3 volts, providing a steady output throughout their lifecycle, which is essential for devices that rely on consistent power levels.

The technologies incorporated in the C2432 and CL2432 models include lithium manganese dioxide chemistry, which enhances their performance and ensures a longer shelf life. These batteries are also designed to perform well under a wide temperature range, ensuring functionality in varying environmental conditions, be it cold or heat. This reliability makes them a preferred choice in critical applications where failure is not an option.

Another key characteristic is their low self-discharge rate, which allows the batteries to maintain stored energy for extended periods. This is particularly advantageous for devices that are used infrequently or that require energy-efficient power sources to maximize their lifespan. With an operational lifespan that can exceed 10 years in certain applications, they perfectly match the needs of devices like memory backup systems and remote controls.

In terms of physical design, both the C2432 and CL2432 feature a standardized coin cell form, which makes them compatible with most devices designed for this battery size. They are also environmentally friendly and can be recycled, aligning with modern sustainability practices.

Overall, the Sanyo C2432 and CL2432 batteries stand out in the market due to their high energy density, advanced lithium technology, long service life, and low self-discharge rates. These features make them an essential component for a variety of electronic devices, solidifying their reputation as a trusted power solution in both consumer and industrial applications.