If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center.

Trouble

 

Possible Cause

 

Remedy

Air conditioner does not

1. Power failure

1.

Restore power.

run at all.

2.

Leakage circuit breaker has tripped.

2.

Contact service center.

 

 

3.

Line voltage is too low.

3.

Consult your electrician or dealer.

 

4.

Operation button is turned off.

4.

Press the button again.

 

5.

The wireless remote controller or

5.

Consult your dealer.

 

 

heat pump is malfunctioning.

 

 

 

6.

Batteries in wireless remote

6.

Replace batteries.

 

 

controller have run down.

 

 

 

 

 

 

Compressor runs but

1. Obstruction in front of condenser coil

1.

Remove obstruction.

soon stops.

 

 

 

 

 

 

 

 

Poor cooling (or heating)

1. Dirty or clogged air filter

1.

Clean the air filter to improve the

performance

 

 

 

airflow.

 

2.

Heat source or many people in room

2.

Eliminate heat source if possible.

 

3.

Doors and/or windows are open.

3.

Shut them to keep the heat (or cold)

 

 

 

 

out.

 

4.

Obstacle near air intake or air

4.

Remove it to ensure good airflow.

 

 

discharge port

 

 

 

5.

Thermostat is set too high for cooling

5.

Set the temperature lower (or higher).

 

 

(or too low for heating).

 

 

 

6.

(Outdoor temperature is too low).

6.

(Try to use a back-up heater.)

 

7.

(Defrosting system does not work.)

7.

(Consult your dealer.)

 

 

 

 

Lamps on the indoor

1. Trouble in wiring system

1.

Contact service center.

unit are flashing.

 

 

 

 

 

 

 

 

 

2Tips for Energy Saving

Avoid

• Do not block the air intake and outlet of the unit. If either is

 

obstructed, the unit will not work well, and may be damaged.

 

• Do not let direct sunlight into the room. Use sunshades, blinds or curtains.

 

If the walls and ceiling of the room are warmed by the sun, it will take

 

longer to cool the room.

Do

• Always try to keep the air filter clean. (Refer to “Care and Cleaning.”)

 

A clogged filter will impair the performance of the unit.

 

• To prevent conditioned air from escaping, keep windows, doors and any

 

other openings closed.

Should the power fail while the unit is running

If the power supply for this unit is temporarily interrupted the unit will automatically resume operation (once the power is restored) with the same settings that were in effect before the power was interrupted.

2 - 18

Image 36
Contents RCS-SH1UA RCS-SH80UG Contents Installation Location Wired type Type 4-WAY Celling panel Optional Air outlet Air intakeType Air outlet Air intake Available for all Indoor unitsSetting Mode buttonSET button ButtonCool mode and dry mode, when the flaps are set in a Timer SET buttonOFF Timer OFF Cycle TimerRemote Control Unit Display Remote Control Unit DescriptionSetting the mode Setting the fan speedSetting the temperature Setting the airflow directionSemi-concealed type Way type Ceiling mounted type T Auto flapVertical directions automatic Horizontal directions manualWall mounted type K Vertical directions automatic Concealed duct type USpecial Remarks Setting the Timer OFF cycle TimerONOperation IndicationCare and Cleaning Air filter How to clean the filterSafety chain Cleaning, be sure to attach the two bolt screwsRemove the air filter attached to the air intake grille LatchShould the power fail while the unit is running Trouble Possible Cause RemedyRCS-SH80UA.WL RCS-BH80UA.WL RCS-SH1UA Contents Product InformationInstallation Location Safety InstructionsElectrical Requirements Remote control receiver Lamp Operation lampStandby lamp Operation controllerSwitch Address switchServicing switches Sweep buttonAutomatically How to Install Batteries Direction marked in the battery compartmentTime, on time, and OFF time are all reset to Direction of the arrowInstallation fitting of wireless remote control unit Place 1here PressTemperature Setting buttonsRemote Cotrol Unit Only for heat pump typeOFF Timer OFF Cycle TimerVent Do not move the flap with your hands SET buttonALL Clear Indication DescriptionSetting the fan speed Setting the temperatureSetting the airflow direction To start the air conditionerOperation without the Wireless Remote Controller Press the ON/OFF operation button againShould the power fail while the unit is running Heating performance DefrostingSetting the Timer TimerOn timer OFF cycleHow to set the OFF timer OperationTroubleshooting 2Tips for Energy SavingTrouble Possible Cause Remedy Obstructed, the unit will not work well, and may be damagedSHA-KC64UG Alert Symbols Installation Location How to Use the System Controller ALL/ZONE/GRCool mode and dry mode, when the flaps are set in a Functions of buttons On buttonOFF button FAN Speed buttonFollows Do not use the SET button for normal operationDisplay Description How to start group operation Stop PowerStop How to start collective operation Set the operation mode by pressing the Mode buttonPage Page Sanyo Fisher Company

RCS-BH80UA.WL, RCS-SH80UA.WL, RCS-SH1UA specifications

Sanyo, a renowned brand known for its innovative heating and cooling solutions, offers a robust lineup of air conditioning systems, notably the models RCS-SH1UA, RCS-SH80UA.WL, and RCS-BH80UA.WL. These models are designed to provide efficient climate control solutions for both residential and commercial applications, emphasizing energy efficiency, comfort, and advanced technology.

The Sanyo RCS-SH1UA is a standout unit equipped with powerful heating and cooling capabilities ideal for varied environments. This compact split system offers a sleek design, making it suitable for small spaces while delivering substantial HVAC performance. One of its significant features is the advanced inverter technology, which adjusts the power consumption based on the current heating or cooling demand, ensuring consistent comfort and energy savings.

On the other hand, the RCS-SH80UA.WL and RCS-BH80UA.WL models are equipped with advanced features to enhance user experience. Both units boast high energy efficiency ratings, which are crucial for reducing electricity bills while minimizing environmental impact. These models incorporate innovative airflow systems that ensure uniform air distribution, creating a pleasant indoor environment regardless of outside conditions.

Both RCS-SH80UA.WL and RCS-BH80UA.WL are designed with user-friendly controls. The inclusion of remote control options allows for convenient adjustments without needing to be near the unit. Additionally, the air conditioning units come with programmable timers and multiple fan speeds, enabling users to fine-tune their climate control experience.

Another noteworthy characteristic across these Sanyo models is their whisper-quiet operation. Designed to minimize noise, they provide a tranquil atmosphere, making them suitable for bedrooms, offices, and other quiet spaces. Furthermore, the air-purifying technologies integrated into these units enhance indoor air quality by reducing pollutants and allergens, promoting a healthier living environment.

In conclusion, the Sanyo RCS-SH1UA, RCS-SH80UA.WL, and RCS-BH80UA.WL air conditioning systems symbolize a blend of efficiency, technology, and user-centric design. With their advanced features and energy-saving capabilities, these models are perfect choices for those aiming to achieve superior climate comfort while being environmentally conscious. Whether you need a system for a small space or a larger area, Sanyo offers reliable solutions that cater to diverse cooling and heating needs.