The screwdriver inputs are software selectable using VS. To enable the push-to-start function, assign the Cycle On input to Input 8, and assign the Cycle Enable input and Clear Outputs input to the Trigger. The typical inputs for a screwdriver with push-to-start function enabled are shown below.