Noise and vibration information for the WSC 70ತA36 (measured in accordance with EN
5 prAA: 2006):
Typical | 108 dB (A) |
Typical | 97 dB (A) |
Uncertainty for the given sound level | 3 dB (A) |
Triaxial vibration values (vibration vector sum) |
|
|
|
Sawing in wood, Ah | < 2.5 m/st |
Uncertainty (K) | 1.5 m/st |
Noise and vibration information for the WSC 55ತA24 (measured in accordance with EN
5 prAA: 2006):
Typical | 106 dB (A) |
| |
Typical | 95 dB (A) |
| |
Uncertainty for the given sound level | 3 dB (A) |
| |
Triaxial vibration values (vibration vector sum) |
|
| |
|
|
|
|
Sawing in wood, Ah |
| < 2.5 m/st |
|
Uncertainty (K) |
| 1.5 m/st |
|
|
|
|
|
Battery | B 36/2.4 NiCd | B 36/3.3 | B 24/2.0 NiCd |
|
|
|
|
Rated voltage | 36 V | 36 V | 24 V |
Capacity | 2.4 Ah | 3.3 Ah | 2 Ah |
Energy capacity | 86.4 Wh | 118.8 Wh | 48 Wh |
Temperature monitoring | NTC | NTC | NTC |
Weight | 2.08 kg | 1.65 kg | 1.37 kg |
Type of cell | |||
No. of cells | 30 | 30 | 20 |
en
5. Safety rules
NOTE
The safety rules in section 5.1 contain all general safety rules for power tools which, in accordance with the applicable standards, require to be listed in the operating instructions. Accordingly, some of the rules listed may not be relevant to this tool.
5.1 General safety rules
WARNING! Read all instructions! Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. The term “power tool” in all of the warnings listed below refers to your mains- operated (corded) power tool or
5.1.1Work area safety
a)Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b)Do not operate power tools in explosive atmo- spheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
c)Keep children and bystanders away while oper- ating a power tool. Distractions can cause you to lose control.
5.1.2Electrical safety
a)Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any