CONNECTING SCROLL SAW TO POWER SOURCE
IMPORTANT: BEFORE CONNECTING THE SAW TO THE POWER LINE, MAKE SURE THE SWITCH IS IN THE “OFF” POSITION.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. To keep this loss to a minimum, make sure the extension cord is in good condition and is a
anda
EXTENSION CORD SIZE
LENGTH OF EXTENSION 120 VOLT WIRE SIZE REQUIRED
| CORD IN FEET | (AWG - American Wire Gage) | ||||
|
|
|
|
|
|
|
0 | - | 25 |
| 18 AWG | ||
| 26 | - | 50 |
| 16 AWG |
|
| 51 | - | 100 |
| 16 AWG |
|
| 101 | - | 150 |
| 14 AWG |
|
|
|
|
|
|
|
|
Fig. 13
GROUNDING INSTRUCTIONS
CAUTION: THIS TOOL MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK.
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with an electric cord having an
Do not modify the plug provided - if it will not fit the out- let, have the proper outlet installed by a qualified electri- cian.
Improper connection of the
con- ductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment grounding conductor to a live terminal.
Check with a qualified electrician or service personnel if the grounding instructions are not completely under- stood, or if in doubt as to whether the tool is properly grounded.
Use only
the tool's plug, as shown in Fig. 14.
Repair or replace damaged or worn cord immediately. If a properly grounded outlet is not available, a temporary adapter, shown in Fig. 15, may be used for connecting the
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.
CAUTION: IN ALL CASES, MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED. IF YOU ARE NOT SURE, HAVE A CERTI- FIED ELECTRICIAN CHECK THE RECEPTACLE.
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE IS LONGEST OF THE 3 BLADES
Fig. 14
GROUNDED OUTLET BOX
GROUNDING MEANS
ADAPTER
Fig. 15