MAINTENANCE
CHANGING THE BLADE
WARNING: USE ONLY
1. | DISCONNECT THE SAW FROM THE POWER |
SOURCE. | |
2. | Rotate lower blade guard (A) Fig. 40, to the top posi- |
tion as shown. | |
3. | Loosen screw (B) Fig. 41, to free plate (C). |
4. | Rotate plate (C) Fig. 42, to the up position as shown. |
5. | Remove arbor screw (D) Fig. 42, by turning screw (D) |
clockwise and at the same time pressing in on arbor lock | |
(E) Fig. 43, to keep arbor from turning. Remove screw (D) | |
Fig. 42, arbor washer (F), outside blade flange (G), and | |
blade (H). Note the position of arbor washer (F) and out- | |
side blade flange (G) as they are removed. DO NOT | |
REMOVE INSIDE BLADE FLANGE. | |
6. | Make sure the inside surfaces of both the inside and |
outside blade flanges are clean and free from any foreign | |
substance. | |
7. | Make sure the inside blade flange is completely on |
arbor with the flats in the flange engaged with the flats on | |
the arbor. | |
8. | Install new blade (H) Fig. 42, outside blade flange |
(G), arbor washer (F) and arbor screw (D). Turn arbor | |
screw (D) counterclockwise to tighten while pressing in |
A
Fig. 40
C
B
Fig. 41
C
F
on arbor lock (E) Fig. 43, to keep arbor from turning. |
IMPORTANT: Make sure flats in outside blade flange (G) |
D
GH
Fig. 42, are engaged with flats on arbor shaft and that |
teeth of saw blade (H) are pointing down at the front, as |
shown in Fig. 42. |
9. Rotate plate (C) Fig. 41, until hook in plate is |
engaged under rubber washer and tighten screw (B). |
10. Place lower blade guard (A) Fig. 40, in the down posi- |
tion. |
Fig. 42
E
Fig. 43
18