Milwaukee 2238-20, 2239-20 manual Symbology, Assembly, Operation, Functional Description

Page 3

General Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C (64°F to 82°F), with relative humidity at 0 % to 85 %.

Maximum voltage between any terminal and earth ground .... 1000 V

Jaw Opening (maximum conductor size) ....

approx. 1.3” (33 mm)

Temperature ....

Operating: -10°C to 50°C (14°F to 122°F)

Storage: -40°C to 60 °C (-40°F to 140°F)

Symbology

To reduce the risk of injury, user must

read operator’s manual.

Double insulation

Risk of electric shock

Indicates that this instrument can clamp

on bare conductors when measuring a

voltage corresponding to the applicable

ASSEMBLY

WARNING Recharge only with the char- ger specified for the battery. For specific charg- ing instructions, read the operator’s manual supplied with your charger and battery.

Inserting/Removing the Battery

To remove the bat-

Fig. 1

tery, use a flat screw-

 

driver to pry open the

 

lock latch. Push in the

 

1.Set the Rotary Dial to position. AC mark is displayed.

2.Press the jaw opening trigger to open the jaws and clamp them onto the conductor under test. The reading is displayed.

NOTE: Do not clamp over 2 or more wires at the same time. Irregular results will occur.

VO

L

T

A

G

E

D

E

T

E

C

T

O

R

Temperature Coefficient .... 0.1 x (specified

accuracy)/°C (<18°C or >28°C) Operating Altitude.... 2,000 meters

Drop Test .... 1 meter

Safety Compliances .... EN61010-1,

UL 61010-1, EN61010-031 (Probes), IEC 61010-2-32 (Clamp Assemblies), IEC/EN 61010-1 2nd Edition for measurement

measurement category, which is marked

next to this symbol.

Earth

Danger, Warning, or Caution - Consult

the operators manual for additional

safety information.

release buttons and

 

pull the battery pack

 

away from the tool.

Lock latch

To insert the battery,

 

slide the pack into the body of the tool. Make sure it latches securely into place. Press in the lock latch to lock the battery in place.

CAUTION Maximum conductor size is about 1.3" diameter. During measurement, keep the jaws fully closed to ensure accurate measurements.

DC Current (Cat. No. 2239-20 only)

Category III, 1000 V, Category IV, 600 V, Pollution Degree 2, EMC EN61326-1

Certifications .... cULus, CE

Voltage: 12 DC Li-Ion, MILWAUKEE Battery

Volts Direct Current

European Conformity Mark

OPERATION

WARNING Always turn the Rotary Dial to OFF before inserting or removing

DANGER To avoid electrical shock: Never make measurement on a circuit in which voltage over 1000V exists.

Pack Cat. Nos. 48-11-2401, 48-11-2402

Battery run time: Greater than 12 hrs with all functions

 

 

 

 

 

Underwriters Laboratories, Inc.,

 

 

 

 

 

United States and Canada

 

 

 

 

 

 

Cat III

Classification of transient overvoltages,

Cat IV

based on nominal line voltage to earth.

 

 

 

 

 

 

Do not dispose of this product as

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unsorted municipal waste.

probes. Only use accessories specifically recommended for this tool. Others may be hazardous.

WARNING

Only use MILWAUKEE test leads with the MILWAUKEE Clamp Meters.

1. Set the Rotary Dial to

position.

DC mark is displayed.

 

2. With the jaws closed and without

clamping them around a conductor,

press the ZERO key to zero adjust

the display.

 

3. Press the jaw opening trigger to

VO

L

T

A

G

E

D

E

T

E

C

T

O

R

FUNCTIONAL DESCRIPTION

Cat. No.

V

2

1.

Current sensing jaws

O

L

2239-20

T

A

 

G

 

2.

NCVD sensing area

E

 

 

D

 

 

E

 

1

T

 

E

 

C

 

3.

NCVD indicator

T

 

Inspect test leads before each use. Use clamp meter to run a continuity test.

Before Use

Confirm the Rotary Dial is set to the correct position, the instrument is set to the correct measurement mode, and the Data hold function is disabled. Oth-

open the jaws and clamp them

around the conductor under test.

NOTE: Do not clamp over 2 or more

wires at the same time. Irregular

results will occur.

4. The reading is displayed.

 

O

 

 

 

 

 

R

 

 

 

 

 

 

4. °F/°C button (2238-20)

 

 

 

Zero button (2239-20)

 

 

3

5. Inrush button (2239-20)

 

4

5

 

6.

Rotary Dial

10

6

7.

Display

 

 

 

8.

Hold button

 

6

 

 

9.

Min/Max button

11

 

 

 

10. Worklight LED

 

 

Cat. No.

11.Jaw opening trigger

 

12. Terminal inputs

12

7

2238-20

 

 

 

 

 

 

 

 

8

9

 

 

 

 

erwise, desired measurement cannot be made.

Making a Measurement

AC Current

DANGER To avoid electrical shock: Never make measurement on a circuit in which voltage over 1000V exists. Clamp tips are designed not to short the circuit under test. If equipment under test has exposed conductive parts, however, extra precaution should be taken to minimize the possibility of shorting.

Disconnect the test leads from the instrument for current measurement.

5.Press the ZERO key again to release the ZERO function.

CAUTION When current flows from the display side to the underside of the meter, the polarity is positive; flow from underside to display side, the polarity is negative.

4

5

Image 3
Contents Cat. No No de Cat 2238-20 2239-20 Operators ManualFunctions Important Safety InstructionsFunctional Description SymbologyAssembly OperationSet PlayedDC Voltage Continuity Set the Rotary Dial toMaintenance Five Year Tool Limited WarrantyAccessories Règles Importantes DE Sécurité FonctionsAvertissement Lire Tous LES Avertissements ET Toutes LES Utilisation SymbologieSpécifications générales Montage DE Loutil000 RésistanceCourant c.c. N˚ de cat -20 seul Tension c.cAccessoires Garantie Limitée DE Cinq ANS Instrucciones ImportantesDE Seguridad EntretienSimbología PrecauciónFunciones Especificaciones generalesFuncionamiento EnsamblajeEnergizado N d aVoltaje Conecte el Tecla Hold RetenciónMantenimiento de la herramienta AccesoriosMantenimiento Garantía Limitada DE Cinco Años DE LA HerramientaMexico Soporte de Servicio Canada Service MilwaukeeRegister your tool online at 416.439.4181