| Table D. Keyboard Functions (continued) | |
Function |
| Procedure |
|
| |
Sequence* | Sequence steps through all 16 cameras. Camera number, camera title, | |
| sequence status, and time/date are shown on the monitor. | |
| Press PREV 4A to step back one camera. Hold for two seconds for a back- | |
| ward sequence. Monitor shows B. Press during sequence to speed up. Press | |
| during a forward sequence to reverse. | |
| Press NEXT 4B to step forward one camera. Hold for two seconds for a for- | |
| ward sequence. Monitor shows F. Press during sequence to speed up. Press | |
| during a backward sequence to go forward. | |
| Press HOLD 4C to hold a sequence. Monitor shows H. Press PREV or | |
| NEXT to resume. | |
| Manually select a camera or press CAM 14 to turn off a sequence. Monitor | |
| shows O. | |
|
| |
Macro Sequence* | Enter 1 or 2 15 and press MACRO 8 to start a group camera sequence. Moni- | |
| tor shows M. Refer to the CM6700 manual for macro/sequence programming. | |
|
| |
Multiplexer | Press SHIFT 2 . Shift key LED 3 lights. The function keys F1 through F5 | |
Displays* | can now be used to display the images from multiple cameras on the monitor. | |
| F1: Zoom | |
| F2: PIP display | |
| F3: Quad display | |
| F4: | |
| F5: | |
|
|
|
Auxiliaries/ | F1 Ð F3 | 5 control only the auxiliaries built into the CM6700 SCU. |
Relays | These outputs can be programmed for momentary, keyed, latched, or alarm | |
| operation. Refer to the CM6700 manual for programming instructions. | |
| F1: Activate/deactivate auxiliary 1 relay.* | |
| F2: Activate/deactivate switcher auxiliary 2 TTL output.* | |
| F3: Activate/deactivate switcher auxiliary 3 TTL output.* | |
| F4 and F5 control the auxiliaries in receivers. | |
| Enter the auxiliary number and press F4 to turn on. Hold, then release for | |
| momentary functions. | |
| Enter the auxiliary number and press F5 to turn off. | |
| In Direct Mode, F1- F3 5 have no function. LED 1 shows auxiliary num- | |
| ber for two seconds after F4 or F5 5 is pressed. | |
|
| |
Acknowledge | Press ACK 16 to acknowledge an alarm. Refer to the CM6700 manual for | |
Alarm* | further information on alarms. | |
|
| |
Program | To program the CM6700 switcher, press PGM 7 . | |
(CM6700) | Follow the programming procedure in the CM6700 manual. LED display 1 | |
| shows P in program mode. Press ACK 16 to exit. | |
|
|
|
LED | LED 1 | shows monitor number (in CM6700 Mode) or camera/receiver number |
| (in Direct Mode) and P (in Program Mode). | |
|
|
|
Firmware Version | LED 1 | flashes for a few seconds to show firmware version on power up |
| (not functional on versions prior to 4.0). | |
|
| |
Clear | Press CLEAR 13 to cancel a number that has been entered. | |
|
|
|