Parker Products OPS1200 user manual Power InputI/O PWR Input

Page 33

OPS1200 INTERCONNECT WIRING

I/O Power Input(I/O PWR INPUT)

I/O PWR INPUT is the connection for the user supplied voltage for the Digital Inputs and Digital Outputs and should be wired to VEXT as shown in the table below. Refer to the ACR1200 Hardware Manual for fuse location and details.

Refer to Figure 1 for connector location. Isolated voltage (VEXT) refers to +24VDC.

￿WARNING

Wiring VEXT with the incorrect voltage will permanently damage the Digital I/O circuitry. The isolated voltage (VEXT) is +24VDC.

Note: I/O PWR INPUT is a 4-pin male circular plug.

I/O PWR INPUT

Isolated Power Connector

Usage

Description

Pin

 

 

 

N/C

No Connection

1

+24VDC EXT

+24VDC Isolated Voltage (VEXT)

2

GND EXT

Isolated Common (GEXT)

3

N/C

No Connection

4

Table 3.5 OPS1200 Isolated Power Connector

Chapter 3, OPS1200 Hardware Interconnection

27

Image 33
Contents OPS1200 User’s Manual This page intentionally left blank Change Notice OPS1200 User’s Manual Table of Contents Figures TablesIntroduction This page intentionally left blank Chapter OPS1200 Display and Keyboard Display OPS1200 LCD Screen Worksheet OPS1200 Displayable Character Set on the LCD Screen Keyboard OPS1200 Keyboard KEY Codes This page intentionally left blank Chapter OPS1200 Firmware Command SET Open Open a devicePRINT, INPUT, Close Clear the LCD screen CLSOpen Sets up the display viewing contrast ContrastSets up the character input timeout value Timeout OPS1200 Display and Keyboard OnlyHpos Move the horizontal cursor positionVPOS, Open Vpos Move the vertical cursor positionHPOS, Open On Menu Goto Sets up the keypad for subroutinesOn Menu Goto Sets up the keypad for Goto statementOn Menu Gosub This page intentionally left blank Chapter OPS1200 Hardware Interconnection OPS1200 Interconnect Wiring Usage Pin Encoder Inputs P1Definition Pin Analog Inputs/Outputs P2Digital Inputs / Outputs P3 Communications P5 PWR Input Power InputI/O PWR InputPower Input Power Input Power PlugAuxiliary Digital Inputs / Outputs XP3 / XP4 XP3-Digital OutputsDigital Inputs / Outputs XP4 -- Digital InputsChapter OPS1200 Technical Specification Technical Specification Chapter OPS1200 Mechanical Drawings 10.3 Cutout Size 10.7 x