Models 110, 111 & 112
Users Manual
Battery Saver ("Sleep Mode")
Rotary Switch Positions
The Meter automatically enters "Sleep mode" and blanks the display if the Meter is not used for 20 minutes. To disable the Sleep mode, hold down the Hz button while turning the Meter on. The Sleep mode is always disabled in the MIN MAX AVG mode.
Terminals
1 | A | COM | V |
|
| 3 | |
|
|
|
10 A
FUSED
2
aej01f.eps
Item | Description |
1 | Input terminal for AC and DC current measurements to |
| 10 A, or to 20 A overload for 30 seconds maximum |
| (Models 111 and 112 only), and for frequency of |
| current. |
2 | Common (return) terminal for all measurements. |
3 | Input terminal for voltage, continuity, resistance, diode |
| test, capacitance, and voltage frequency |
Switch Position
K
Hz (button)
L
Hz (button)
R
e
G
E
(Models 111 & 112)
?
Hz (button)
(Models 111 & 112)
A
Hz (button)
Measurement Function
AC voltage from 300 mV to 600 V. Frequency from 5 Hz to 50 kHz.
DC voltage from 1 mV to 600 V. Frequency from 5 Hz to 50 kHz.
Beeper turns on at < 20 Ω and turns off at > 250 Ω.
Ohms from 0.1 Ω to 40 MΩ.
Diode test. Displays OL above 2.4 V.
Farads from 1 nF to 9999 μF.
AC current from 3 A to 10 A.
(20 A overload for 30 seconds maximum.) >10.00 display flashes.
>20 A, OL is displayed. Frequency from 50 Hz to 5 kHz.
DC current from 0.001 A to 10 A.
(20 A overload for 30 seconds maximum.) >10.00 display flashes.
>20 A, OL is displayed. Frequency from 50 Hz to 5 kHz.
measurements. |
Notes: AC voltage and current
2