Thermo Products 9678BNWP manual Required Equipment

Page 4

Required Equipment

1.Thermo Scientific Orion pH/mV meter, such as the 3-Star pH meter, 4-Star pH/ISE meter, 4-Star pH/DO meter, 4-Star pH/conductivity meter or 5-Star pH/ISE/DO/conductivity meter.

ORP electrodes can be used on any pH/mV meter with a BNC or U.S. standard connection. The electrodes can also be used on meters with a variety of inputs when an adapter cable is used. Visit www.thermo.com/water for details.

Refillable ORP Triodes have temperature connectors that are compatible with specific meters, refer to the list below.

2.Thermo Scientific Orion ORP electrode.

The 9180BNMD and 9179BNMD ORP/ATC Triode electrodes have a temperature connector that is compatible with the Star Series meters.

The 9180BN and 9179BN ORP/ATC Triode electrode have a temperature connector that is compatible with the A+ Series meters.

3.ORP electrode filling solution. Use Cat. No. 900011 filling solution for samples that have a total ionic strength greater than 0.2 M. Use Cat. No. 900001 filling solution for samples that have a total ionic strength less than 0.2 M.

ORP electrode filling solution is not required if using a 9179BNMD or 9179BN low maintenance ORP/ATC Triode

4.ORP standard, Cat. No. 967901 or 967961.

ORP standard is highly recommended to ensure accurate ORP measurements.

5.Beakers, plastic or glass.

6.Magnetic stirrer or Orion stirrer probe, Cat. No. 096019. The stirrer probe can be used with 3-Star, 4-Star and 5-Star benchtop meters.

7.Distilled or deionized water.



Redox/ORP Electrode User Guide

Image 4
Contents User Guide Page Introduction Epoxy Refillable ORP/ATC Triode Cat. No Bnmd and 9180BNRequired Equipment Sample Requirements Electrode Preparation for Refillable Electrodes Electrode PreparationElectrode Preparation for Gel-Filled Electrodes Refillable ORP Electrode Electrode Calibration ORP Standard ValuesRedox/ORP Electrode User Guide Measurement Techniques Electrode Measurements Direct MeasurementsOxidation-Reduction Titrations References Typical Redox Titration Methods Unknown Interferences Suitable Titrants Titration Reaction Electrode Maintenance General Cleaning Electrode Cleaning ProceduresCleaning Solutions Sure-Flow Electrode Cleaning Cat. No Bnwp Disassembling the Sure-Flow ElectrodeElectrode Storage Short-term Storage up to one dayLong-term Storage over one day Reassembling the Sure-Flow ElectrodeTroubleshooting MeterElectrode Sample/ApplicationAssistance Warranty Checking Electrode OperationOrdering Information Thermo Fisher Scientific