Agilent Technologies 08495-90025 Maximum SWR, Maximum Residual Attenuation, RF Power Handling

Page 13

Specifications

Maximum SWR

Instrument

Frequency Range (GHz)

Maximum SWR

 

 

 

8495G

dc to 4

1.35

 

 

 

8495H

dc to 8

1.35

 

8 to 12.4

1.5

 

12.4 to 18

1.7

 

 

 

8494G,

dc to 4

1.5

8496G

 

 

 

 

 

8494H,

dc to 8

1.5

8496H

8 to 12.4

1.6

 

12.4 to 18

1.9

 

 

 

Maximum Residual

Attenuation

Instrument

Maximum Residual Attenuation

 

 

8494G,

0.6 dB + 0.09 dB/GHz

8494H

 

 

 

8495G,

0.4 dB + 0.07 dB/GHz

8495H

 

 

 

8496G,

0.6 d8 + 0.09 dB/GHz

8496H

 

 

 

Attenuation Repeatability ±0.01 dB typical after 5 million cycles

RF Power Handling

1 W average, 100 W peak with maximum pulse width of 10 microseconds

Capability

(all models)

 

 

 

Solenoid Drive

 

 

 

 

 

 

 

 

 

 

Solenoids Drive

Coil Voltage

Switching Current

 

 

 

 

 

 

All models

20 to 30 Vdc

125 mA1 at 24V

 

(approximately)

 

(190Ω, 65 mH)

1. For serial number prefixes below 1722S, change 125mA to 110mA.

8494/95/96G/H Operating And Service Manual 7

Image 13
Contents Agilent Technologies 8494/95/96G/H Attenuators Restricted Rights Legend What You’ll Find in This Manual… Certification Documentation Warranty WarrantySafety and Regulatory Information Service and SupportInstrument Markings Safety Earth Ground Before Applying PowerOverview SpecificationInstruments Covered by ManualTypical Four Section Attenuator Schematic Diagram 8495G/H Attenuator Sections 8494G/H Attenuator Sections8496G/H Attenuator Sections 8496G/H Attenuator Switching OrderInstrument Options Option Connector DescriptionFrequency Range Attenuation SpecificationsAttenuation Accuracy Maximum SWR RF Power HandlingMaximum Residual Attenuation CapabilitySection Solenoid Cable ConnectorAtten CardCharacteristic Physical CharacteristicsInstrument Dimensions Weight Depth x width x height Operating ValueInitial Inspection Mating Connectors InstallationInstallation Instructions Operator’s Check Operating InstructionsDescription Meter Indication dB Minimum SWR Meter RangeMaximum Performance Tests AdjustmentsDescription Part Number Replaceable PartsTroubleshooting ServiceRepair To care for the device To disconnectReplacing Amphenol 7 mm Center Contact Replacing Connector Outer Shell Dimensions