HP 8 II 1411 manual Packaging and transporting guidelines

Page 16
Removal and replacement preliminary requirements

Packaging and transporting guidelines

Follow these grounding guidelines when packaging and transporting equipment:

To avoid hand contact, transport products in static-safe tubes, bags, or boxes.

Protect ESD-sensitive parts and assemblies with conductive or approved containers or packaging.

Keep ESD-sensitive parts in their containers until the parts arrive at static-free workstations.

Place items on a grounded surface before removing items from their containers.

Always be properly grounded when touching a component or assembly.

Store reusable ESD-sensitive parts from assemblies in protective packaging or nonconductive foam.

Use transporters and conveyors made of antistatic belts and roller bushings. Be sure that mechanized equipment used for moving materials is wired to ground and that proper materials are selected to avoid static charging. When grounding is not possible, use an ionizer to dissipate electric charges.

Workstation guidelines

Follow these grounding workstation guidelines:

Cover the workstation with approved static-shielding material.

Use a wrist strap connected to a properly grounded work surface and use properly grounded tools and equipment.

Use conductive field service tools, such as cutters, screw drivers, and vacuums.

When fixtures must directly contact dissipative surfaces, use fixtures made only of static- safe materials.

Keep the work area free of nonconductive materials, such as ordinary plastic assembly aids and Styrofoam.

Handle ESD-sensitive components, parts, and assemblies by the case or PCM laminate. Handle these items only at static-free workstations.

Avoid contact with pins, leads, or circuitry.

Turn off power and input signals before inserting or removing connectors or test equipment.

10 Chapter 4

Image 16
Contents HP 8 G21411 Tablet Product notice Software termsSafety warning notice Iv Safety warning notice Table of contents Power cord set requirements Product description Category Description ServiceabilityOperating system External component identification Illustrated parts catalog Tablet major components 785180-001Miscellaneous parts Sequential part number listingSequential part number listing Service considerations Removal and replacement preliminary requirementsTools required Typical electrostatic voltage levels Grounding guidelinesEvent 10% 40% 55% Packaging and transporting guidelines Equipment guidelines Material Use Voltage protection levelRemoval and replacement procedures Tablet component replacement proceduresBack cover Description Spare part numberPage Battery Power/volume button board Front-facing webcam Page Rear-facing webcam Speakers System board Page Page Specifications Factory data reset Backing up and recovering your dataUpdating apps, widgets, and the operating system Power cord set requirements Requirements for all countriesRequirements for specific countries and regions Country/region Accredited agency Applicable note numberPower cord set requirements Recycling Index