HP 3586A manual Filter Band Width Carrier Offset

Page 18

The difference is caused by the different way telephone and radio people denote SSB cannel frequency. When comparing a SSB radio frequency with a HP3586 frequency on LSB the HP3586 will have a fixed negative offset from the receiver’s whose value depends on the filter that is selected in the HP3586. On USB the HP3586’s frequency offset will be positive by the same filter offset. This is because the HP3586 in the selective modes defines a cannel by its center frequency where SSB receivers and transmitters use the convention of defining the channel by the carrier frequency.

Filter offset values can be used to obtain the carrier frequency used by radio SSB transmitters and receiver by adding or subtracting it from the HP3586 display frequency readings. These carrier offset numbers are shown below for each of the HP3586 filters that can be used for SSB:

FILTER BAND WIDTH

CARRIER OFFSET

1740Hz

1350Hz

2000Hz

1500Hz

3100Hz

1850Hz

9.4Setting a AM Transmitter’s Carrier to a SSB frequency - To better understand this let’s go through an example of zero beating an AM transmitter with a SSB signal. Assume I want to check into the Collins Collectors Association net on LSB at 3895kHz. The net control operator and most of the members are on LSB but welcome anyone to check in on AM as long as they have a stable signal and are zero beat with the net control operator so they can be copied on LSB by the net members. Tonight there is a QSO down a few KHz below the net so the net control has moved the net up an unknown number of Hz and it’s hard to determine his exact frequency because I’m using my 75A4 receiver with an analog frequency dial. I can usually get to within 100Hz using it but even that will cause complaints by those on LSB, especially those that don’t like AM. So I want to get as close as possible to their frequency with my BC-610F AM transmitter which is hooked to a HP3586.

I tune close to the SSB signal of the net control operator using a frequency keyboard entry then the method describer in section 4.11 of chapter 4. I next enter into my hand held calculator the frequency displayed on my HP3586, which is 3896KHz. Since I’m using my 3100Hz filter and on LSB, I use my calculator to add a carrier offset of 1850Hz to the HP3586C’s frequency of 3896Kz to get the SSB stations carrier frequency of 3897.850KHz. I then enter the calculated SSB net’s carrier frequency into my HP3586C using the following commands, press [FREQ], enter 3897.850 on the keyboard, press [KHz], and finally press [MEAS CONT] to place the new filter center RF frequency and internal tracking oscillator frequency into the HP3586’s frequency register. I now turn down the volume of my HP3585’s speaker since the SSB signal will be detuned by 1850Hz and use my 75A4 receiver to monitor the net. Now the filter center frequency and the frequency of the rear panel output to my transmitter is right on the SSB net’s frequency so my AM transmitter’s carrier frequency will be zero beat with the net control’s frequency. Then most stations on the net will not even realize I’m using AM. This example should illustrate a way to work around the different methods of measuring SSB channel frequency used by telephone and radio technicians using the HP3586C.

9.4Frequency Shift During Auto Cal - When transmitting AM to a SSB station using a HP-3586 with the instrument’s auto cal function is on, the instrument’s output frequency will change about 100Hz up and down in frequency during the 3 second auto cal cycle. For this reason I find it best to press [AUTO CAL] to turn off auto cal during AM transmissions. I usually leave auto cal off after the instrument has warmed up for a half hour when transmitting to SSB stations just after I have set my carrier frequency. Auto cal is only necessary after a large change in frequency and during level measurements.

18

Image 18
Contents Version 2.0, September Table of Contents Introduction Description of the HP3586 Page Selective Signal Connections Front Panel Description and Initial SET UP Page Page Setting and Measuring Frequency Page Power Level Measurements Using the Selective Mode Page Voltage Level Measurements Using the Selective Mode Measuring Carrier Signal Strength Tuning SSB Signals Using the Selective Mode Filter Band Width Carrier Offset Tuning a SSB Signal Using the NOISE/DEMODULATION Mode Measuring Audio Noise Using the Wideband Mode Measuring Impulse Noise Measuring Audio Harmonic Distortion Page Passive and Active Network Analysis Page Measuring a TRANSMITTER’S Spurious Emissions Page Selection of Measurement Modes and Other Considerations Page Page Appendix a Understanding the Decibel Ratio Measuring SystemNumber Ratio Power DB Ratio Page HP3586 Error Codes Appendix BSchematics for Useful HP3586 Accessories Appendix C
Related manuals
Manual 258 pages 14.72 Kb Manual 174 pages 33.79 Kb Manual 8 pages 30.64 Kb Manual 88 pages 20 Kb Manual 11 pages 52.74 Kb Manual 122 pages 13.19 Kb

B, 3586A, C specifications

The HP C3586A and C3586B tape drives are notable components in the realm of data storage solutions, primarily designed for enterprise-class environments. These SCSI (Small Computer System Interface) tape drives are regarded for their efficiency, reliability, and capacity to meet the growing demands of data backup and archival processes in businesses.

The C3586A model utilizes the DAT (Digital Audio Tape) technology, which allows it to deliver high performance and high data density. It features a native capacity of 2.3 GB per cartridge, which can be extended to 4.6 GB with the use of compression. This is particularly advantageous for businesses requiring significant amounts of data storage without the necessity for multiple tapes. The transfer rate is rated at up to 12 MB per minute, which ensures quick backups and restores, minimizing the operational downtime.

In terms of data integrity and security, both models incorporate advanced error correction techniques to guarantee that data remains pristine and intact throughout the storage duration. They are designed to work seamlessly with a variety of operating systems and backup applications, enhancing compatibility and user convenience.

The HP C3586B, on the other hand, offers similar foundational technologies but with enhanced features. It supports higher capacity tapes and is engineered to work seamlessly in high-performance environments. With the integration of SCSI-2 interfacing, users can expect faster data transfer rates, which is critical for organizations dealing with large volumes of data.

Another key aspect of both models is their rugged design, which provides durability and reliability needed for long-term storage solutions. The drives are built to withstand extended usage, which makes them a cost-effective choice for businesses looking to invest in dependable data storage systems.

Furthermore, these drives come with a user-friendly interface and straightforward maintenance. This allows IT personnel to handle backups with ease while keeping the workflow uninterrupted.

In summary, the HP C3586A and C3586B tape drives epitomize the union of technology, usability, and dependability. Their robust features, including high data capacity, fast transfer rates, and durable construction, make them a formidable choice for enterprises seeking efficient data backup and archival solutions in the ever-evolving digital landscape.