HP 3586A, B, C manual Measuring Audio Noise Using the Wideband Mode

Page 20

11.MEASURING AUDIO NOISE USING THE WIDEBAND MODE

11.1General – All versions HP3586 can be used to measure total power input over their entire frequency range of 200Hz to 32MHz by placing them into the wideband measuring mode. This mode is useful for rapidly measuring a signal whose frequency isn’t important or is determined by tuned circuits like in an IF stage as a digital wide band power or voltage meter. However, in this mode the instrument’s noise floor is very much higher, around –70dbm, than in the other selective modes where it’s around –120dbm. This could cause errors in measuring weak signals. In the following example we will illustrate how to use the wideband mode when measuring an audio line amplifier’s internal noise.

In the wideband mode all the front panel frequency dependent displays and controls are deactivated. The instrument in the wideband mode is a broadband power or voltage measuring instrument with a frequency response of 200Hz to 32MHz.

11.2Wideband Amplifier Noise Measurement – Assume we have an amplifier that we can input 200Hz to 10KHz audio signals from an audio device to and amplify this signal up to a 2.5 watts 75 ohm of audio output power. This amplifier has a 600 ohm input and a 75 ohm output impedances, a 20db gain, and it uses a socket mounted inexpensive audio IC chip that we can buy from different sources. We want to select the chip that has the lowest internally generated noise. We’ll use our HP3586 to measure the noise performance of our amplifier with different chips in its wideband measurement mode.

First we terminate the input of our amplifier with a 600 ohm resistor and attach a scope to its output to be sure there is only internal noise generated by the amp from its output. Any of signals with a total power of over .5 watts will damage out HP3586 so we want to be sure there is nothing but low power white noise on the amps output. We now connect the AC coupled 75 ohm output to the termination sub panel 75 ohm connector. We next press [75 ohm] on the termination sub panel to provide a 75 ohm load for our amplifier. We next press [WIDE BAND] on the measurement mode sub panel. We also press [dbm] on the measurement/entry sub panel for units since we’ll start by measuring the noise power in db relative to a miliwatt.

11.3Normalizing our Noise Data - We now should see a low level reading in dbm units on the LED of the measurement entry sub panel. Let’s say its –50.1dbm, which is about as low as our HP3586 can accurately measure in the wideband mode since the internal wideband noise floor on my HP3586B appears to be around 70dbm. Also the 100db measuring range is only available in the wideband mode so the resolution of our level data will only be .1db. We’ll now let the instrument compare the IC’s for us and also pick up a little more accuracy since we are down so low in power level that the HP3586 is starting to loose accuracy for absolute readings. Let’s offset the HP3586 display to read in db’s compared to our first standard chip.

To do this we could enter the –50.1dbm offset using the keyboard, but there is an easier way using one button to transfer the displayed offset directly into the offset register. Go to the entry keyboard and press [RDNGOFFSET] to transfer the measurement display’s level into the offset register. Now press [OFFSET] on the measurement/entry sub panel to activate the level offset feature. With our amplifier still powered and connected to our HP3586 we now see the LED display reading is 0db. We also should see O behind the dbm annunciator indicating the reading has been offset and is not in dbm but is now in db compared to the noise power from our amplifier with the IC chip we want to compare the others to.

11.4Taking the Data – We now can proceed to plug in the other chips one at a time and record db readings for each. We see readings between +15db and –6db above and below our reference IC chip. It looks like the one that is –6db is the best choice for low noise.

20

Image 20
Contents Version 2.0, September Table of Contents Introduction Description of the HP3586 Page Selective Signal Connections Front Panel Description and Initial SET UP Page Page Setting and Measuring Frequency Page Power Level Measurements Using the Selective Mode Page Voltage Level Measurements Using the Selective Mode Measuring Carrier Signal Strength Tuning SSB Signals Using the Selective Mode Filter Band Width Carrier Offset Tuning a SSB Signal Using the NOISE/DEMODULATION Mode Measuring Audio Noise Using the Wideband Mode Measuring Impulse Noise Measuring Audio Harmonic Distortion Page Passive and Active Network Analysis Page Measuring a TRANSMITTER’S Spurious Emissions Page Selection of Measurement Modes and Other Considerations Page Page Appendix a Understanding the Decibel Ratio Measuring SystemNumber Ratio Power DB Ratio Page HP3586 Error Codes Appendix BSchematics for Useful HP3586 Accessories Appendix C
Related manuals
Manual 258 pages 14.72 Kb Manual 174 pages 33.79 Kb Manual 8 pages 30.64 Kb Manual 88 pages 20 Kb Manual 11 pages 52.74 Kb Manual 122 pages 13.19 Kb

B, 3586A, C specifications

The HP C3586A and C3586B tape drives are notable components in the realm of data storage solutions, primarily designed for enterprise-class environments. These SCSI (Small Computer System Interface) tape drives are regarded for their efficiency, reliability, and capacity to meet the growing demands of data backup and archival processes in businesses.

The C3586A model utilizes the DAT (Digital Audio Tape) technology, which allows it to deliver high performance and high data density. It features a native capacity of 2.3 GB per cartridge, which can be extended to 4.6 GB with the use of compression. This is particularly advantageous for businesses requiring significant amounts of data storage without the necessity for multiple tapes. The transfer rate is rated at up to 12 MB per minute, which ensures quick backups and restores, minimizing the operational downtime.

In terms of data integrity and security, both models incorporate advanced error correction techniques to guarantee that data remains pristine and intact throughout the storage duration. They are designed to work seamlessly with a variety of operating systems and backup applications, enhancing compatibility and user convenience.

The HP C3586B, on the other hand, offers similar foundational technologies but with enhanced features. It supports higher capacity tapes and is engineered to work seamlessly in high-performance environments. With the integration of SCSI-2 interfacing, users can expect faster data transfer rates, which is critical for organizations dealing with large volumes of data.

Another key aspect of both models is their rugged design, which provides durability and reliability needed for long-term storage solutions. The drives are built to withstand extended usage, which makes them a cost-effective choice for businesses looking to invest in dependable data storage systems.

Furthermore, these drives come with a user-friendly interface and straightforward maintenance. This allows IT personnel to handle backups with ease while keeping the workflow uninterrupted.

In summary, the HP C3586A and C3586B tape drives epitomize the union of technology, usability, and dependability. Their robust features, including high data capacity, fast transfer rates, and durable construction, make them a formidable choice for enterprises seeking efficient data backup and archival solutions in the ever-evolving digital landscape.