HP B, C, 3586A manual Voltage Level Measurements Using the Selective Mode

Page 15

7.VOLTAGE LEVEL MEASUREMENTS USING THE SELECTIVE MODE

7.1General - The HP3586 can only output level measurements in db’s referenced to a power like one miliwatt, one picowatt, or a voltage level like .775 volt on all models and a 1 volt input on the C version. But remember that every level reading is only in db referenced to a power or voltage level. If you’re not familiar with this comparative nonlinear system of measurement, take a look at Appendix A for a better understanding. Now let’s do a couple of examples of voltage measurements.

A very important consideration is that if we were going to do a voltage measurement of a very high impedance tuned circuit where the instrument’s unterminated 10K 50pf input would load or detune, we need to insert a one to one probe or amplifier to isolate the HP-3586’s input. In Appendix C I’ve shown the schematics of two circuits you may want to consider to isolate the circuit under test from you instrument.

7.1Performing the Measurement - First let’s use the first example of the padded output oscillator in the previous example. This is very easy to do by first recalling our configuration stored in the 1 location by pressing [RECALL], entering 1 on the keyboard. We first need to change the measurement units for voltage measurements, press [db.775V] on the measurement/entry sub panel. If the offset button’s light is on, press this button to deactivate the offset calculation. Now our readings of the oscillator’s output will be in units of db referenced to .775 volts. We can easily calculate the level in volts using a calculator and the following formula:

Level in volts = 20 anti log (Vr /. 775) Where Vr is the display panel reading in db.775V units.

15

Image 15
Contents Version 2.0, September Table of Contents Introduction Description of the HP3586 Page Selective Signal Connections Front Panel Description and Initial SET UP Page Page Setting and Measuring Frequency Page Power Level Measurements Using the Selective Mode Page Voltage Level Measurements Using the Selective Mode Measuring Carrier Signal Strength Tuning SSB Signals Using the Selective Mode Filter Band Width Carrier Offset Tuning a SSB Signal Using the NOISE/DEMODULATION Mode Measuring Audio Noise Using the Wideband Mode Measuring Impulse Noise Measuring Audio Harmonic Distortion Page Passive and Active Network Analysis Page Measuring a TRANSMITTER’S Spurious Emissions Page Selection of Measurement Modes and Other Considerations Page Page Understanding the Decibel Ratio Measuring System Appendix aNumber Ratio Power DB Ratio Page Appendix B HP3586 Error CodesAppendix C Schematics for Useful HP3586 Accessories
Related manuals
Manual 258 pages 14.72 Kb Manual 174 pages 33.79 Kb Manual 8 pages 30.64 Kb Manual 88 pages 20 Kb Manual 11 pages 52.74 Kb Manual 122 pages 13.19 Kb

B, 3586A, C specifications

The HP C3586A and C3586B tape drives are notable components in the realm of data storage solutions, primarily designed for enterprise-class environments. These SCSI (Small Computer System Interface) tape drives are regarded for their efficiency, reliability, and capacity to meet the growing demands of data backup and archival processes in businesses.

The C3586A model utilizes the DAT (Digital Audio Tape) technology, which allows it to deliver high performance and high data density. It features a native capacity of 2.3 GB per cartridge, which can be extended to 4.6 GB with the use of compression. This is particularly advantageous for businesses requiring significant amounts of data storage without the necessity for multiple tapes. The transfer rate is rated at up to 12 MB per minute, which ensures quick backups and restores, minimizing the operational downtime.

In terms of data integrity and security, both models incorporate advanced error correction techniques to guarantee that data remains pristine and intact throughout the storage duration. They are designed to work seamlessly with a variety of operating systems and backup applications, enhancing compatibility and user convenience.

The HP C3586B, on the other hand, offers similar foundational technologies but with enhanced features. It supports higher capacity tapes and is engineered to work seamlessly in high-performance environments. With the integration of SCSI-2 interfacing, users can expect faster data transfer rates, which is critical for organizations dealing with large volumes of data.

Another key aspect of both models is their rugged design, which provides durability and reliability needed for long-term storage solutions. The drives are built to withstand extended usage, which makes them a cost-effective choice for businesses looking to invest in dependable data storage systems.

Furthermore, these drives come with a user-friendly interface and straightforward maintenance. This allows IT personnel to handle backups with ease while keeping the workflow uninterrupted.

In summary, the HP C3586A and C3586B tape drives epitomize the union of technology, usability, and dependability. Their robust features, including high data capacity, fast transfer rates, and durable construction, make them a formidable choice for enterprises seeking efficient data backup and archival solutions in the ever-evolving digital landscape.