HP Type K02, Class SMF, Class MMS and MRS, Type F02 Combination Starters Nema Sizes, Dimensions

Page 14

AC Controls

Combination Starters (NEMA Sizes 0–4)

General / Dimensions

Combination Starter With Type MCS Disconnect Switch

Dimensions

Combination Starter With ETI Circuit Breaker

The Type ETI circuit breaker, sometimes called a Motor Circuit Interrupter, is

a device designed specifically for applica- tion in motor circuits. The ETI is a magnetic only protective device designed to provide protection against short circuit current.

The instantaneous-only type ETI circuit breaker employs adjustable magnetic trip settings to allow broader application ranges and a higher degree of motor short circuit protection.

Table 15.25 3-Phase Magnetic Motor Starter

NEMA

 

Maximum Horsepower

Starter

Half

 

 

 

Size

Size

200V

230V

460/575V

0

0

3

3

5

1

1

7.5

7.5

10

1 34*

1 34

10

10

15

2

2

10

15

25

2 12*

2 12

15

20

30

3

3

25

30

50

3 12*

3 12

30

40

75

4

4

40

50

100

Type MCS Disconnect Switches

Type MCS Disconnect Switches feature a quick-make, quick-break mechanism to insure proper switch operation. With a high fault withstand rating of 100 kA at 480 volts ac, when fused with Class R rated size fuses, MCS switches meet stringent industry standards set forth by the automotive, petro-chemical, and pulp and paper industries.

With visible blade contacts for ease of inspection, removable line shields, and front removable fuse clips and lugs, disconnect switches are UL recognized and CSA certified. They are available with Class H, J, and R fuse kits for a wide range of fused, non-fused, and over- fusing options.

Table 15.26 Magnetic Motor Starter

 

Dimensions in Inches (mm)

 

Size

A

B

C

NEMA 1

0 –134

23.25

11.00

7.63

General

 

(591)

(279)

(194)

Purpose

 

 

 

 

2, 2 12

26.75

12.13

7.63

Standard

Width 0–4

 

(679)

(308)

(194)

 

3

31.50

12.50

7.63

 

(800)

(318)

(194)

 

 

NEMA 1

 

 

 

 

General

3 12 , 4

48.97

12.13

9.94

Purpose

Standard

 

(1244)

(308)

(252)

 

 

 

 

Width 312–4

 

 

 

 

NEMA 12

0 – 212

29.50

12.13

7.69

Industrial

 

(749)

(308)

(195)

Use

 

 

 

 

Standard

3

34.25

12.50

7.69

Width 0–4

 

(870)

(318)

(195)

NEMA 12

 

 

 

 

Industrial

312 , 4

48.94

19.13

9.94

Use

Standard

 

(1243)

(486)

(252)

Width 312–4

 

 

 

 

15

AC Controls

CSI Section 16160

Siemens Electrical Products and Systems

297

 

Specification Guide

 

Image 14
Contents General Manual Starters and SwitchesTypical Wiring Diagrams AC Controls Class SMF Heater Elements Horsepower RatingsManual Starters and Switches Features Two Unit Devices Nema Type 1 General Purpose Enclosure DimensionsGeneral Purpose Flush Mounting General Purpose Flush Mounting for Two Unit DevicesManual Motor Starter Switches Dimension / Wiring DiagramsTechnical Data General / Dimensions3VU13 Enclosure Dimensions Manual Motor Starter ProtectorClass 11 Manual Motor Starters General / Wiring DiagramsManual Motor Starters and Contactors Motor Starters Coil Data Magnetic ContactorsApplications 14 Reference LiteratureLighting and Heating Contactors Compact Magnetic Contactors Lighting 21 2-12 Pole DimensionsWiring Diagrams Typical 21WE 2-12 PoleCLM Contactors 300 and 400 Amperes, 2- and 3-Pole Magnetic Latch Operation Combination Lighting and Heating FeaturesDescription Ballast LoadDimensions Combination Starters Nema SizesContactors Non-Reversing Key Features27 Contactor Technical Data Starters Key Features Cont’dMagnetic Motor Starters Full Voltage Non Reversing Size 0 through Magnetic Motor Starters-Full Voltage Non ReversingAuxiliary Equipment Pole Single Phase Magnetic Contactors Size Dimensions / Wiring DiagramsContactor Dimensions Sizes 2-31/2 Pole 3 Phase Magnetic Contactors Size 4 1/ 2Enclosure Dimensions Enclosures303 Full Voltage, Non-Reversing Starters Nema Sizes RatingsMulti-Speed Starters Nema Sizes Torque Characteristics33 3-Phase Multi-Speed Starter Combination Multi-Speed StarterPart Winding Starter Auto Transformer StarterWye Delta Starter OperationShorted SCRa Phase LossSolid-State Reduced Voltage Starters Pump Stopa36 Solid-State Reduced Voltage Starters Pilot Device Units and Indicator Lights Type 3SBO Pilot Device UnitsEnclosed Pilot Device Stations Enclosed Pilot Device StationsGuide Form Specifications SpecificationsReduced Voltage Wye Delta Starters Reduced Voltage Autotransformer StartersMulti-Speed Starters Reduced Voltage, Part Winding Starters