HP Type K02, Class SMF, Class MMS and MRS, Type F02 Dimensions, General Purpose Flush Mounting

Page 4

AC Controls

Manual Starters and Switches

Table 15.5 General Purpose Flush Mounting

 

 

 

Dimensions

 

 

Type of

 

in Inches (mm)

 

Device

Operator

Type

A

B

C

Class

 

FF1, 1P, 2, 2P

1.44

2.75

4.50

SMF

Toggle

FS1, 1P, 2, 2P

(37)

(70)

(114)

Fractional

 

 

 

 

 

1.44

3.50

5.25

HP Starter

 

FSJ1P, 2P

 

(37)

(89)

(133)

 

 

 

 

 

FF3, 3P, 4, 4P

1.44

2.75

4.50

 

Key

FS3, 3P, 4, 4P

(37)

(70)

(114)

 

FSJ3P, 4P

1.44

3.50

5.25

 

 

 

 

(37)

(89)

(133)

 

 

 

Class

 

KF1, 1A, 1B, 2, 2B, 2C

1.75

2.75

4.50

MMS

Toggle

FS1, 1A, 1B, 2, 2B, 2C

(44)

(70)

(114)

Motor

 

 

 

 

 

1.75

3.50

5.25

Starting

 

KSJ1A, 1B, 2B, 2C

 

(44)

(89)

(133)

Switch

 

 

 

 

KF3, 3A, 3B, 4, 4B, 4C

1.75

2.75

4.50

 

Key

FS3, 3A, 3B, 4, 4B, 4C

(44)

(70)

(114)

 

KSJ3A, 3B, 4C, 4C

1.75

3.50

5.25

 

 

 

 

(44)

(89)

(133)

 

 

 

Table 15.6 Two Unit Devices

NEMA Type 1 General Purpose Enclosure

 

Type of

 

 

Device

Operator

Class

Type

One Starter

Toggle

SMF

FG02, 02P

 

Key

SMF

FG04P

Two Starters

Toggle

SMF

FG222, 222P

 

Key

SMF

FG44P

One Str. and

Toggle

SMF

FG71, 71P, 72, 72P

One Sel. Sw. a

Key

SMF

FG74P

Reversing Switch b

Toggle

MRS

KG11, 11A, 11B, 22, 22A, 22B

 

 

 

22C

Two Speed Starter

Toggle

SMF

FG11, 11P, 22, 22P

Two Speed Switch

Toggle

MMS

KG11, 11A, 11B, 22, 22B, 22C

aSelector switch is on left, increases overall depth to 3.5 in. (89mm) b Only one pilot light (located on right) is used on MRS switches.

Table 15.7 General Purpose Flush Mounting for Two Unit Devices

 

 

 

 

Dimensions

 

 

 

Type of

 

 

in Inches (mm)

 

 

Device

Operator

Class

Type

A

B

C

D

Two

Toggle

SMF

FF22, 22P

5.25 (133)

3.75 (95)

5.25 (133)

1.44 (37)

Starters

 

 

 

 

 

FS22P

4.56 (116)

3.50 (89)

4.50 (114)

1.44 (37)

 

 

 

 

Key

SMF

FF44P

5.25 (133)

3.75 (95)

5.25 (133)

1.44 (37)

 

FS44P

4.56 (116)

3.50 (89)

4.50 (114)

1.44 (37)

 

 

 

One

Toggle

SMF

FF71, 71P, 72, 72P

5.25 (133)

0.75 (19)

5.25 (133)

2.00 (51)

Starter

FS71P, 72P

4.56 (116)

3.50 (89)

4.50 (114)

2.00 (51)

and One

 

 

 

 

FF74P

5.25 (133)

3.75 (95)

5.25 (133)

2.00 (51)

Selector

Key

SMF

Switch 3

FS74P

4.56 (116)

3.50 (89)

4.50 (114)

2.00 (51)

Reversing

 

 

KF11, 11A, 11B

 

 

 

 

Switch

Toggle

MRS

KF 22, 22A

5.25 (133)

3.75 (95)

5.25 (133)

1.75 (44)

 

 

 

22B, 22C

 

 

 

 

Two

Toggle

SMF

FF11, 11P, 22

5.25 (133)

3.75 (95)

5.25 (133)

1.44 (37)

Speed

22P

Starter

 

 

 

 

 

 

Two

 

 

KF11, 11A, 11B

5.25 (133)

3.75 (95)

5.25 (133)

1.75 (44)

Speed

Toggle

MMS

22, 22B, 22C

Switch

 

 

 

 

 

 

3Selector switch is on left, extends 1.62 in (41 mm) from mounting surface.

CSI Section 16160

Siemens Electrical Products and Systems

 

Specification Guide

Dimensions

15

AC Controls

287

Image 4
Contents Typical Wiring Diagrams Manual Starters and SwitchesGeneral AC Controls Manual Starters and Switches Features Horsepower RatingsClass SMF Heater Elements Dimensions General Purpose Flush MountingTwo Unit Devices Nema Type 1 General Purpose Enclosure General Purpose Flush Mounting for Two Unit DevicesManual Motor Starter Switches Dimension / Wiring DiagramsGeneral / Dimensions 3VU13 Enclosure DimensionsTechnical Data Manual Motor Starter ProtectorManual Motor Starters and Contactors General / Wiring DiagramsClass 11 Manual Motor Starters Motor Starters Magnetic Contactors ApplicationsCoil Data 14 Reference LiteratureLighting and Heating Contactors 21 2-12 Pole Dimensions Wiring Diagrams TypicalCompact Magnetic Contactors Lighting 21WE 2-12 PoleCLM Contactors 300 and 400 Amperes, 2- and 3-Pole Combination Lighting and Heating Features DescriptionMagnetic Latch Operation Ballast LoadDimensions Combination Starters Nema Sizes27 Contactor Technical Data Key FeaturesContactors Non-Reversing Magnetic Motor Starters Full Voltage Non Reversing Key Features Cont’dStarters Auxiliary Equipment Magnetic Motor Starters-Full Voltage Non ReversingSize 0 through Dimensions / Wiring Diagrams Contactor DimensionsPole Single Phase Magnetic Contactors Size Sizes 2-31/2 Pole 3 Phase Magnetic Contactors Size 4 1/ 2Enclosure Dimensions Enclosures303 Full Voltage, Non-Reversing Starters Nema Sizes RatingsTorque Characteristics 33 3-Phase Multi-Speed StarterMulti-Speed Starters Nema Sizes Combination Multi-Speed StarterAuto Transformer Starter Wye Delta StarterPart Winding Starter OperationPhase Loss Solid-State Reduced Voltage StartersShorted SCRa Pump Stopa36 Solid-State Reduced Voltage Starters Pilot Device Units and Indicator Lights Type 3SBO Pilot Device UnitsEnclosed Pilot Device Stations Enclosed Pilot Device StationsGuide Form Specifications SpecificationsReduced Voltage Autotransformer Starters Multi-Speed StartersReduced Voltage Wye Delta Starters Reduced Voltage, Part Winding Starters