HP Type F02, MMS and MRS, Class SMF, Type K02 Dimensions / Wiring Diagrams, Contactor Dimensions

Page 18

Magnetic Contactors

Dimensions / Wiring Diagrams

Fig 1a

Fig 1b

Fig 2

Side Mounted

B1 Front Mounted AuxAux Contact

Contact

B2 Aux Contact and 1

Aux Power Pole

Right or Left Side

Optional

Electrical

Contacts

 

Table 15.29

Contactor Dimensions

 

 

 

 

 

 

 

 

 

 

Dimensions in Inches (mm)

 

 

NEMA

Half

 

 

 

Type

 

A

 

B

 

C

 

Size

Size

Figure

 

 

 

3.75

(95)

5.50

(140)

3.19 (81)

00

 

1a

 

 

 

4.31

(109)

4.75 (121)

3.75

(95)

0–1

 

1b

 

 

 

4.31 (109)

4.75 (121)

3.75

(95)

 

13/4

1b

 

 

 

4.88 (124)

4.25 (110)

4.00

(102)

2

 

1b

 

Open

 

4.88

(124)

4.50

(114)

4.00

(102)

 

21/2

1b

 

 

6.13

(156)

5.50

(140)

5.06

(129)

3

 

1b

 

 

 

 

 

 

 

6.13

(156)

5.50 (140)

5.06

(129)

 

31/2

1b

 

 

 

7.81

(198)

5.50

(140)

5.75

(146)

4

 

2

 

 

 

 

17.38

(441)

7.88

(200)

 

41/2

2

 

 

 

 

17.38

(441)

7.88

(200)

5

 

2

 

 

 

 

22.50 (572)

10.00

(254)

6

 

2

 

2 Pole Single Phase Magnetic Contactors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size 00

 

Sizes 0–13/4

 

 

Sizes 2–31/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Pole 3 Phase Magnetic Contactors

Size 00

Size 0–4

Size 41/2, 5

Size 6

CSI Section 16160

Siemens Electrical Products and Systems

 

Specification Guide

15

AC Controls

301

Image 18
Contents Manual Starters and Switches Typical Wiring DiagramsGeneral AC Controls Horsepower Ratings Manual Starters and Switches FeaturesClass SMF Heater Elements Two Unit Devices Nema Type 1 General Purpose Enclosure DimensionsGeneral Purpose Flush Mounting General Purpose Flush Mounting for Two Unit DevicesManual Motor Starter Switches Dimension / Wiring DiagramsTechnical Data General / Dimensions3VU13 Enclosure Dimensions Manual Motor Starter ProtectorGeneral / Wiring Diagrams Manual Motor Starters and ContactorsClass 11 Manual Motor Starters Motor Starters Coil Data Magnetic ContactorsApplications 14 Reference LiteratureLighting and Heating Contactors Compact Magnetic Contactors Lighting 21 2-12 Pole DimensionsWiring Diagrams Typical 21WE 2-12 PoleCLM Contactors 300 and 400 Amperes, 2- and 3-Pole Magnetic Latch Operation Combination Lighting and Heating FeaturesDescription Ballast LoadDimensions Combination Starters Nema SizesKey Features 27 Contactor Technical DataContactors Non-Reversing Key Features Cont’d Magnetic Motor Starters Full Voltage Non ReversingStarters Magnetic Motor Starters-Full Voltage Non Reversing Auxiliary EquipmentSize 0 through Pole Single Phase Magnetic Contactors Size Dimensions / Wiring DiagramsContactor Dimensions Sizes 2-31/2 Pole 3 Phase Magnetic Contactors Size 4 1/ 2Enclosure Dimensions Enclosures303 Full Voltage, Non-Reversing Starters Nema Sizes RatingsMulti-Speed Starters Nema Sizes Torque Characteristics33 3-Phase Multi-Speed Starter Combination Multi-Speed StarterPart Winding Starter Auto Transformer StarterWye Delta Starter OperationShorted SCRa Phase LossSolid-State Reduced Voltage Starters Pump Stopa36 Solid-State Reduced Voltage Starters Pilot Device Units and Indicator Lights Type 3SBO Pilot Device UnitsEnclosed Pilot Device Stations Enclosed Pilot Device StationsGuide Form Specifications SpecificationsReduced Voltage Wye Delta Starters Reduced Voltage Autotransformer StartersMulti-Speed Starters Reduced Voltage, Part Winding Starters