Chapter 2. Cabling the RAID Subsystem Cluster Components
2.3 HUB-Radiant RAID Cluster Layout - (SCSI Interconnect)
To connect two HP host servers to a RAID subsystem via use of a Hub (e.g., a
1.Attach (compatible) end of the 5M adapter cable
2.Connect the other end of the adapter cable to a convenient hub port.
3.Attach the compatible end of the short adapter cable
4.Connect the other end of the short adapter cable to the end of an UltraSCSI cable
5.Attach the remaining end of the UltraSCSI cable to a convenient hub port.
6.Connect one end of an UltraSCSI cable
7.Attach the other end of the UltraSCSI cable to the remaining hub port.
8.Connect a terminator
Figure 2–2 Hub-Radiant RAID Cluster Layout - (SCSI Bus Interconnect)
HOST A
H D 68 H ost
Ada p ter
BN 3 8 C
VH D C
UltraSCSI HUB
B N 37A
Tr
RA7000 or ESA10000
Subsystem
HOST B
H D 6 8 H ost
A da pter
BN 38 E
V H D C
A da pte r C a ble
B N 37 A
V H D C
U ltraS C SI C a b le
BN 3 7A
Te rm inato r
H 8 8
SHR
NOTE: In hub configurations, termination is internal to the hub.