HP File System Extender (FSE) manual See Also Fserestore8, fsebak8, fserecover8, fseintro7

Page 17

2.2 NAME

16

/var/opt/fse/lock/backup.pid (on Linux systems), %InstallPath%\var\lock\backup.pid (on Windows systems) FSE backup lock file.

2.2.6COPYRIGHT

Copyright (C) 2004-2005 Hewlett-Packard

Copyright (C) 2002-2005 GRAU Data Storage

2.2.7SEE ALSO

fserestore(8), fsebak(8), fserecover(8), fseintro(7).

File System Extender 3.2 Command Line Reference

Image 17
Contents File System Extender Contents Fse -startrestore FSE command documentationFse -full-access VolumeNameName Process FSE Daemon Partition Manager S Back End Agent S Library Agent SStart OptionsStop Restart StartrestoreStatus MountLimit-access VolumeNameName Umount MountPointFse -mountI\fs02 Volume86eec883-a640-11d7-9be3-00096bb08bc0 Full-accessFse -dismount-ntfsVolumed9568629-da27-11d7-bf21-0050da45607 Fse -limit-accessVolumed9568629-da27-11d7-bf21-0050da45607Name Files See Also Fsesystem8, fsepartition8, fserestore8, fseintro7Media Barcode... -c- -client Client... -skip Name Media Hsmlvvar = hsmvg/varHsmlvpart = hsmvg/part Skip-hsmfs ClientLog-file HelpFsebackup -media000202 -l /tmp/backup000202.log Fsebackup -media000123 000124Fsebackup -media 000123 000124 000125 -client See Also Fserestore8, fsebak8, fserecover8, fseintro7 Fsebak -change-medium BarcodeBarcode JobIOR JobIORResuming a Normal FSE System Operation fsebak -continue Achieving the FSE Database Consistency fsebak -suspendContinue SuspendStatusCode Reserve-mediumComplete-job JobIORFsebak -suspend Fsebak -continueFsebak -complete-job IOR010000000a00 Fsebak -reserve-medium backup-003Fsebak -change-mediumbackup-105 IOR010000000e00 Checking Consistency of the File System Catalog Fsc-media Fsc-hsmfsPartitionName Match-media Name AutocorrectFsecheck -fsc-hsmfs dailyreports Fsecheck -fsc-media archivepart32See Also fserecover8, fseintro7 Name Add ConfigFileNameConfigFileName AddRemove NameRevisionNumber Name ShowHistory ModifyName Detail DisableEnable DriveAB -F Libdrive01See Also Fse8, fselibrary8, fsemedium8, fsepool8, fseintro7 FileName Path -idPartitionName FileID... -datePath Name FileName FileID Into DateMigid Migrate PathRelease Trigger-migrationNo-monitor Fsefile -list updateMe.gz -detailName Trigger-deletion Tmp/fsedeletedfiles Fsefile -recallFSEPartition010 30600 -date 2002/12/10 Fsefile -trigger-migration Fsefile -Sweek50 week51 /mnt/fsevg/weekly-archives/week52Partition03 Fsefile -trigger-deletion partitiondeleteme -F -no-monitorDecr Number JobIDPriority JobID Number Name Recovery List recovery jobs Maint Migration List migration jobs Recall List recall jobs AdminAbort JobIDPriority NumberFsejob -l -A partitionnew -D Name DecrFsejob -abort20021126000803 Fsejob -priority 20021206000614See Also Fsesystem8, fsepartition8, fsefile 8, fseintro7 Name ConfigFileName Name RevisionNumber -H- -historyName of the FSE library configuration file to use Name of the FSE library to manage configuration for Show-inventory Rescan LibraryNameFselibrary -r libsupplemental -force Name VersionFselibrary -show systemlib Fselibrary -list -DDisable the FSE library named AITlibrary skip confirmation Fselibrary -update-inventory libemail -rescanFselibrary -disable AITlibrary -force Enable the currently disabled FSE library named LTOlibraryVolumeNumber Barcode VolumeNumberDescription Pool PoolName Volume Format Force Close-volume VolumeNumberMark-unreliable Mark-unusableReorg Recreate-friDuplicate Fsemedium -r backuptape78 -F Name Copy-contentsFsemedium -add backuptape05 Fsemedium -close-volume ait60 Fsemedium -init tape4a -volume 1 -no-monitorFsemedium -format work35 -F -init Fsemedium -i workoffline45 -forceFsemedium -copy-contents damagedmed Fsemedium -reorg tape56 -volume 1 2 5Fsemedium -duplicate tape44 copytape44 -no-monitor Fsemedium -reorg tape55 -no-monitorName SlackThreshold% Name Name Options Add Partition states have the following meaningDisable option Show List Reorg-scan Name StatusExpirationDate NumberOfGenerationsFsepartition -addclient02part05.fse Name Reorg-statSlackThreshold% Fsepartition -r client03part03 -force Fsepartition -disable client03astropics -FFsepartition -show client01part02 Fsepartition -status mailpartition01Fsepartition -reorg-scantemporarypart 2004/07/15 Fsepartition -enableclient01temporarystoreFsepartition -reorg-scanverytemporarypart 2003/09/20 100000 Fsepartition -reorg-stat client03astropics FilesName Fsepool -s Fsepool -aFsepool -r Options Add Name of the FSE media pool configuration file to use List Fsepool -addmailarchivepool.fse Fsepool -show projarchivepool -H Fsepool -remove systembackuppool -FFsepool -l -D Fsepool -reorg-stat FilesOpt/fse/newconfig/fse-pool-LTO.cfg InstallPath%\newconfig \fse-pool-LTO.cfgName Fsejob -a jobID Limitations Fserecover -hsmfs fsefs01 Fserecover -fsc fsefs01Name Options Fsc HsmfsFserestore Fserestore -h -help Options Help See Also Fse8, fsebackup8, fserecover8, fsebak8, fseintro7 Name Status Partition PART. Manager HSM FS Error Options Show Enable-dbgSysDbgFile SysDbgLevelSysDbgHSMFS SysDbgFlagsDisable-dbg Fsesystem -mfseconfignew.fse Fsesystem -show fseconfig.fseName See Also Fse8, fsejob8, fsepartition8, fseintro7
Related manuals
Manual 115 pages 39.56 Kb Manual 328 pages 27.8 Kb Manual 92 pages 24.26 Kb Manual 26 pages 22.37 Kb

File System Extender (FSE) specifications

HP File System Extender (FSE) is a sophisticated solution designed to optimize data storage management for enterprises that deal with large volumes of unstructured data. This technology addresses the challenges of data growth and the need for effective data retention strategies, enabling organizations to store and manage their information more efficiently.

One of the main features of HP FSE is its ability to intelligently migrate data between primary and secondary storage. By utilizing policies that determine when to move infrequently accessed files to lower-cost storage environments, FSE helps reduce the strain on primary storage systems and saves on costs associated with high-performance storage solutions. This tiered approach to data management ensures that organizations can access the data they need quickly while still maintaining an efficient overall storage architecture.

Another notable characteristic of HP FSE is its seamless integration with existing storage infrastructures. The solution works with a variety of storage systems, allowing organizations to utilize their current investments without the need for significant changes to their infrastructure. This interoperability is powered by advanced technologies that facilitate data migration and retrieval, ensuring a smooth transition for organizations looking to optimize their storage strategies.

Additionally, HP FSE is equipped with robust reporting and analytics capabilities. This functionality provides organizations with insights into their storage usage, helping them understand data patterns and optimize their storage environments accordingly. By having visibility into which files are accessed most frequently and which are rarely used, organizations can make informed decisions on data retention policies and storage management.

Security is paramount in data management, and HP FSE addresses this concern by implementing advanced data protection features. This includes data encryption, secure access controls, and compliance with industry regulations, ensuring that sensitive information is safeguarded throughout its lifecycle.

Overall, HP File System Extender is a comprehensive data storage solution that combines intelligent data management, seamless integration, insightful analytics, and robust security features. By leveraging these capabilities, organizations can efficiently manage their unstructured data, lower costs, and enhance operational efficiency, making it an invaluable tool in today’s data-driven landscape.