Sigma ML750 instruction manual Care of Your Opener

Page 21

CARE OF YOUR OPENER

When properly installed, opener will provide high performance with a minimum of maintenance. The opener does not require additional lubrication.

Limit and Force Settings: These settings must be checked and properly set when opener is installed. Weather conditions may cause some minor changes in the door operation, requiring some re-adjustments, particularly during the first year of operation.

Refer to Setting the Limits and Force on page 5. Follow the instructions carefully and repeat the safety reverse test after any adjustment.

Remote Control: The remote control may be secured to a car sun visor with the clip provided. Additional remotes can be purchased at any time for use in all vehicles using garage. Refer to Accessories. Any new remotes must be programmed into the opener.

Remote Control Battery: The lithium batteries should produce power for up to 5 years. If transmission range decreases, replace battery.

To Change Battery: To replace batteries, use the visor clip or screwdriver blade to pry open the case. Insert batteries positive side up. To replace cover, snap shut along both sides. Do not dispose of the old battery with household waste. Take batteries to a proper disposal center.

MAINTENANCE OF YOUR OPENER

Once a Year:

Apply grease to rail and trolley

Oil door rollers, bearings and hinges

DO NOT lubricate the opener itself

DO NOT APPLY grease to the door tracks

OPERATION OF YOUR OPENER

Your opener can be activated by any of the following devices:

The Backlit Door Control Button. Hold the button down until door starts to move.

The Outside Keylock or Keyless Entry System (if you have installed either of these accessories).

The Remote Control Transmitter. Hold the push button down until the door starts to move.

Opening the Door Manually:

Door should be fully closed if possible. Weak or broken springs could allow an open door to fall rapidly. Property damage or serious personal injury could result.

The door can be opened manually by pulling the release handle down and back (toward the opener). To reconnect the door, pull the release handle straight down.

Do not use the manual release handle to pull the door opener or closed.

When the Opener is Activated by Remote Control or Backlit Door Control Button:

1.If open, the door will close. If closed, the door will open.

2.If closing, the door will stop.

3.If opening, the door will stop (allowing space for entry and exit of pets and for fresh air).

4.If the door has been stopped in a partially open or closed position, it will reverse direction.

5.If an obstruction is encountered while closing, the door will reverse.

6.If an obstruction is encountered while opening, the door will reverse, then stop.

7.The optional Protector System™ uses an invisible beam which, when broken by an obstruction, causes a closing door to open and prevents an open door from closing. It is STRONGLY RECOMMENDED for homeowners with young children.

Allow a 15 minute cooling period after 5 continuous operations of the opener.

The opener light will turn on: 1. when opener is initially plugged in; 2. when the power is briefly interrupted; 3. when the opener is activated.

The light turns off automatically after 2-1/2 minutes. Bulb size is 24V/21W maximum.

SPECIFICATIONS

Input Voltage

230-240 VAC, 50Hz

Max. Pull Force

700N

Power

115W

Standby Power

5.5W

Normal Torque

7Nm

 

Motor

Type

DC gearmotor permanent lubrication

 

Drive Mechanism

Drive

Belt with two-piece trolley on

 

steel rail.

Length of Travel

Adjustable to 2.3m

Travel Rate

127-178mm per second

Lamp

On when door starts, off 2-1/2 minutes

 

after stop.

Door Linkage

Adjustable door arm. Pull cord trolley release.

 

Safety

Personal

Push button and automatic stop in down

 

direction. Push button and automatic stop in

 

up direction.

Electronic

Automatic force adjustment

Electrical

Transformer overload protector and low

 

voltage push button wiring.

Limit Device

Optical RPM/Passpoint detector.

Limit Adjustment

Electronic, Semi and Fully Automatic.

Start Circuit

Low voltage push button circuit.

 

Dimensions

Length (Overall)

3.2m

Headroom Required

30mm

Hanging Weight

16kg

 

Receiver

Memory Registers

12

Operating Frequency

433.92MHz

SPECIAL NOTE: Chamberlain strongly recommends that the protector system be installed on all garage door openers.

21

Image 21
Contents N2966 Start by Reading These Important Safety Instructions Before You Begin Door TypesTools Required Hardware Provided Completed InstallationInstall the Belt Assemble the RailInsert Trolley & Idler Pulley Bracket Into Rail Fasten Rail to Opener and Install Belt Attach Trolley to RailAttach Sprocket Cover Header Bracket Positioning Install Header Sleeve and Tighten BeltAttach Rail to Header Bracket Install the Header BracketHang the Opener Position the OpenerInstall Light Connect Electric PowerAttach Emergency Release Rope & Handle Fasten Door BracketAssemble Door Arm ONE-PIECE Door InstallationInstall Door Control optional Remote Control Wall Mount BracketOperation of the Door Control To Erase all Remote Control Codes Using the Multi-Function Door ControlProgram your Opener & Remote Channel RemoteProgram your Keyless Entry Optional Using the Wall-Mounted Door ControlSetting the Force Setting the LimitsTest the Safety Reverse System Force limit test liftingSpecial Features Install the Protector SystemDoor within a door connection Flashing light connectionWiring Instructions for Accessories Accessories001A5060-15 Replacement Parts204C0161-2 Trouble Shooting Care of Your Opener 114A3458-ANZ