Installation

Installation Location

Indoor Unit

1.The inlet and outlet should not be covered so that the outflow air can reach all parts of the room.

2.Install in a location from which the condensation water can be drained out conveniently and that is permitting easy connection with the outdoor unit.

3.Avoid a location where there is heat source, steam or inflammable gas.

4.Install in a location where it can withstand the full weight and vibration of the unit.

5.Be sure to leave enough space to allow access for routine maintenance. The height of the installation should be 7.55 feet or more away from the floor.

6.Install in a location where it is 3.28 feet or more away from other electric appliances such as television, audio devices, etc.

7.Select a location where it is easy to remove and clean the filter.

8.Be sure that the installation conforms to the installation dimension diagram.

9.The plug should be accessible after the appliance is positioned.

Outdoor Unit

10.Select a location from which noise and outflow air emitted by unit will not inconvenience neighbors.

11.Select a location where there should be sufficient ventilation.

12.The inlet and outlet should not be covered.

13.The location should be able to withstand the full weight and vibration of the outdoor unit and permit safe installation.

14.There should be no danger of flammable gas or corrosive gas leaks.

15.Be sure that the installation conforms to the installation dimension diagram.

- 9 -

Image 11
Contents Indoor Unit Outdoor Unit Wall Mounted Mini Split Heat Pump Air ConditionerTable of Contents Name of Each Part Structure and OperationInstructions before Use Adjust the guide louver and change KFIHP-09-ID KFHHP-12-ID KFIHP-09-OD KFHHP-12-OD Specification and Technical DataFunction-Remote control Remote Control OperationRemote Control Operation How to Insert Batteries Operation General procedureOutdoor Unit Installation LocationIndoor Unit Grounding Requirement Electric WiringImportant Notes Installation Dimension DiagramInstallation Installation Install the Indoor Unit Electric wiring connection Install the Outdoor UnitInstall the connection pipe Air Purging and Leakage Test Test Operation Test Operation and Check after InstallationCare and Maintenance Care and MaintenanceCheck before Use Trouble ShootingProblem Trouble ShootingTrouble Shooting Trouble Shooting Electrical Schematic Diagram Indoor Unit Electrical Schematic Diagram Outdoor Unit Warranty