Soleus Air KFHHP-09-OD, KFHHP-12-ID, KFHHP-12-OD, KFIHP-09-ID Specification and Technical Data

Page 6

Specification and Technical Data

 

Model

 

 

KFIHP-09-ID

 

KFHHP-12-ID

 

 

 

KFIHP-09-OD

 

KFHHP-12-OD

 

 

 

 

 

 

 

 

Function

 

 

 

 

 

Cool / Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessory

 

 

 

 

 

Air Cleaner

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity (Btu/h)

 

 

9000

 

12000

 

 

 

 

 

 

 

 

 

 

 

Heating capacity (Btu/h)

 

 

9500

 

13000

 

 

 

 

 

 

 

 

 

 

 

Power Supply (V)

 

 

115V~

 

208~230

 

 

 

 

 

 

 

 

 

 

 

 

Frequency (Hz)

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

Cooling/Heating rated current(A)

 

12/13.6

 

9/10

 

 

 

 

 

 

 

 

 

 

Cooling/Heating rated power(W)

 

1250/1450

 

1700/1750

 

 

 

 

 

 

 

 

 

 

Cooling/Heating power input(W)

 

730/840

 

1100/1200

 

 

 

 

 

 

 

 

 

 

Recycling air Volumem3/h

 

 

550

 

 

Refrigerant and weight(lbs)

 

 

R410A

2.6 lbs

 

R410A 2.8 lbs

 

 

 

 

 

 

 

 

 

 

 

 

Water proof level

 

 

 

 

 

IP24

 

 

 

 

 

 

 

 

 

 

 

 

Noise(Indoor/Outdoor)dB(A)

 

 

 

43/55

 

 

 

 

 

 

 

 

 

 

 

 

 

Climate type

 

 

 

 

 

T1

 

 

 

 

 

 

 

 

 

 

 

Anti-electric shock protection

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight Indoor/Outdoor)(lbs)

 

 

24.3/99.2

 

24.3/99.2

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

Indoor unit

 

 

30.31”×7.48”×9.84”

 

32.68”×8.86”×11.22”

(W x D x H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

33.39”×12.6”×21.26”

 

33.39”×12.6”×21.26”

Connection Pipe:

 

 

 

 

 

 

 

 

Length (ft)

 

 

 

 

 

19.68

 

 

 

 

Gas additional charge(oz/ft)

 

 

 

0.16

 

 

 

 

Outer Diameter

 

 

Liquid Pipe (mm)

Φ6(1/4”)

 

 

 

 

 

Gas Pipe (mm)

 

Φ12(1/2”)

 

 

 

 

 

 

 

 

 

 

 

Max Distance

 

 

Height (ft)

 

16.4

 

 

 

 

 

 

Length (ft)

 

49.21

 

 

 

 

 

 

 

 

 

 

 

 

1.

All above are tested and certified to ETL specification.

 

 

2.

All above could be changed without notice; the latest specifications are on the nameplate of your air conditioner.

3.

When the unit is restarted after it stopping, it can automatically resume the last running mode, and the outdoor unit

 

starts later.

 

 

 

 

Working temperature range:

 

 

 

 

 

Indoor side DB/WB(°F)

Outdoor side DB/WB(°F)

 

 

 

 

 

 

 

 

 

Maximum cooling

89.6 / 73.4

109.4 / 78.8

 

 

 

Minimum cooling

69.8 / 59

69.8 / -

 

 

 

Maximum heating

80.6 / -

75.2 / 64.4

 

 

 

Minimum heating

68 / -

23 / 21.2

 

- 4 -

Image 6
Contents Wall Mounted Mini Split Heat Pump Air Conditioner Indoor Unit Outdoor UnitTable of Contents Structure and Operation Name of Each PartInstructions before Use Adjust the guide louver and change Specification and Technical Data KFIHP-09-ID KFHHP-12-ID KFIHP-09-OD KFHHP-12-ODRemote Control Operation Function-Remote controlRemote Control Operation How to Insert Batteries General procedure OperationInstallation Location Indoor UnitOutdoor Unit Electric Wiring Grounding RequirementInstallation Dimension Diagram Important NotesInstallation Installation Install the Indoor Unit Install the Outdoor Unit Install the connection pipeElectric wiring connection Air Purging and Leakage Test Test Operation and Check after Installation Test OperationCare and Maintenance Care and MaintenanceTrouble Shooting Trouble ShootingProblem Check before UseTrouble Shooting Trouble Shooting Electrical Schematic Diagram Indoor Unit Electrical Schematic Diagram Outdoor Unit Warranty