C01. Crrige
Purpose ( Calibrate the temperature from which the printhead has to be warmed.
THIS CALIBRATION MUST BE DONE WITH THE PRINTHEADS INSTALLED.
If •C0100 OK" ( Calibration done.
If •C01xx il" ( Perform Electronics test.
C02. Refill
Purpose ( To ensure the correct position of the carriage assembly in respect to the refill assembly.
When the Carriage Assembly, Refill Assembly or the Electronics Assembly is ordered, a Refill Calibration Tool, a special Carriage height gauge and an Instructions flyer will be included. You must follow the instructions in the flyer in order to correctly calibrate the Refill Assembly and to make sure that the Carriage is at the correct height.
C03. Line Sensor
Purpose ( Calibrate the intensity of the line sensor in the carriage PCA.
Load white media before performing this calibration
WINDOW MUST CLOSED BEFORE YOU PERFORM THIS CALIBRATION
REPLACE THE LENS COVER BEFORE YOU PERFORM THIS
CALIBRATION IN ORDER TO PREVENT ANY AEROSOL PROBLEMS
If •C0300 Done" ( Calibration done.
C04. Service Sttion
THIS CALIBRATION IS NO LONGER VALID AND SHOULD NEVER BE
PERFORMED
C05. Printheds Alignment
Purpose ( To test and if necessary correct the misalignment between the printheads.
WINDOW MUST CLOSED BEFORE YOU PERFORM THIS CALIBRATION
If •C0500 Done" ( Calibration done.
If •C0501 il" ( If the calibration pattern is bad, try recovering printheads using the front(panel menu and try the calibration again. If the calibration pattern is bad again, then replace the complete Ink Delivery System of the color that is bad. Perform Electronics Test. Perform Line Sensor Test.
HP DesignJet 2500CP and 2000CP Printers | Quick Reference Service Manual 13 |