Soleus Air GM-WAC-10ESE-C, GM-WAC-12ESE-C If AC is Blocked by Storm Window, Air Conditioner Use

Page 10
If AC is Blocked by Storm Window

If AC is Blocked by Storm Window

Add wood as shown in FIG. 14, or remove storm window before air conditioner is installed.

AIR CONDITIONER USE

Operating your air conditioner properly helps you to obtain the best possible results.

This section explains proper air conditioner operation.

IMPORTANT:

FIG. 14

SASH

STORM WINDOW

FRAME

OR OTHER

OBSTRUCTION

BOARD THICKNESS AS REQUIRED, FOR PROPER PITCH TO REAR, ALONG ENTIRE SILL. FASTEN WITH NAILS OR SCREWS.

If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This prevents the air conditioner from blowing a fuse or tripping a circuit breaker.

Do not try to operate your air conditioner in the cooling mode when outside temperature is below 65°F (18°C). The inside evaporator coil will freeze up, and the air conditioner will operate properly.

NOTE: In the event of a power failure, your air conditioner will operate at the previous settings when the power is restored.

If Storm Window Frame must remain, be sure the drain holes or slots are not caulked or painted shut.Accumulated Rain Water or Condensation must be allowed to drain out.

Removing AC From

Window

*Turn AC off, and disconnect power cord.

*Remove sash seal from between windows, and unscrew safety lock.

*Remove screws installed through frame and frame lock.

*Close (slide) side panels into frame.

*Keeping a firm grip on air conditioner, raise sash and carefully “rock” air conditioner backward to drain any condensate water in base of unit. Be careful not to spill any remaining water while lifting unit from window. Store parts WITH air conditioner.

9

Image 10
Contents Electronic Window Air Conditioner Models GM-WAC-10ESE-C GM-WAC-12ESE-COperating Instructions Page IMPORTANT SAFETY INSTRUCTIONS Recommended Ground Method ELECTRICAL REQUIREMENTSLCDI Power Cord and Plug It is the customer’s responsibilityPACKING LIST Packing ListModel SPECIFICATIONSDISCLAIMER GM-WAC-10ESE-CINSTALLATION & ASSEMBLY INSTRUCTIONS TOOLS NEEDED Mounting HardwareHow to Install FIG. 3AFIG. FIG FIG. FIG. 6AFIG. FIG AIR CONDITIONER USE If AC is Blocked by Storm WindowRemoving AC From Window Electronic Control Panel & Remote Control USING YOUR AIR CONDITIONERAir Conditioner Controls Normal Operating Sounds OPERATING YOUR AIR CONDITIONER REMOTE CONTROL9.LOCK/UNLOCK- Press the “+” and “-”buttons simultaneously to lock and unlock the remote control. When the remote is locked, none of the functions or setting can be changed using the remote REMOTE CONTROLOPERATING YOUR AIR CONDITIONER USING YOUR AIR CONDITIONER Cont Cabinet Cleaning CARE AND CLEANINGAir Filter Cleaning Winter StorageSOLUTIONS TROUBLESHOOTINGPROBLEM The Remote Control is not workingSOLUTIONS TROUBLESHOOTING CONTPROBLEM POSSIBLE CAUSESWarranty