Soleus Air KFHIP-09-OD Installation, Install the rear panel, Install the piping hole

Page 14
◆Installation

Installation

Install the rear panel

 

 

1.

Always mount the rear panel horizontally.

 

 

 

Because the mouth of drainage pipe is at the left

 

 

 

side and the left side of the rear panel is better to

 

 

 

adjust slightly lower.

 

 

2.

Fix the rear panel on the selected location with

50

50

 

screws supplied with the unit.

 

 

3.

Be sure that the rear panel has been fixed firmly

 

 

 

enough to withstand the weight of an adult of

 

 

 

132.3 lbs; furthermore, the weight should be

 

 

 

evenly shared by each screw.

 

 

 

 

 

 

Install the piping hole

1.Make the piping hole Φ50in the wall at a slight downward slant to the out door side. (Shown in Fig. 1)

2.Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole.

Install the drainage hose

1.For well draining, the drain hose should be placed at a downward slant.

2.Do not wrench or bend the drain hose or flood its end by water.

3.The extended drainage pipe in the room should be wrapped with the insulating materials.

Install the connection pipes

Connect the connection pipes with the relevant union pipes of the indoor unit and tighten the flare nut of the connection pipes (Shown in P16 “Install the connection pipes”).

NOTE:

1.Connect the connection pipes with the indoor unit first and the outdoor unit second.

2.Be careful in bending the connection pipes, or you will damage the pipes.

3.Do not over tighten the flare nut. There is a possibility of leakage.

Electric wiring

1.Open the surface panel.

2.Remove the fixed screw from the wiring cover as shown at the right side.

3.Route the power connection cord from the back of the indoor unit and pull it toward the front through the wiring hole for connection.

-12 -

Image 14
Contents Wall Mounted Mini Split Heat Pump Air Conditioner Indoor Unit Outdoor UnitOPERATING AND INSTALLATION MANUAL Model KFIHP-09-ID / KFHIP-09-ODTABLE OF CONTENTS Structure and Operation Name of Each PartThe Instructions before Use The Instructions before Use Set the room temperature appropriatelyKFIHP-09-ID Specification and Technical DataModel KFHHP-12-IDRemote Control Operation Function-RemotecontrolRemote Control Operation Continued How to Insert Batteries Operation The general procedureProcedure for SLEEP mode Indoor Unit InstallationInstallation Location Outdoor UnitElectric Wiring Grounding Requirement112.6 inch 212.6 inch Installation Dimension DiagramImportant Notes Install the piping hole InstallationInstall the rear panel Install the drainage hoseInstallation 6.Recover the surface panelInstall the Indoor Unit Electric wiring connection Install the Outdoor UnitInstall the connection pipe Tightening Torque TableAir Purging and Leakage Test Install the Outdoor UnitTest Operation Test Operation and Check after InstallationCheck after Installation 1.Before Test OperationCare and Maintenance Care and MaintenanceProblem Care and Maintenance ContinuedTrouble Shooting Trouble ShootingTrouble Shooting Trouble ShootingProblem Because the air of the room is cooled down rapidlyTrouble Shooting Unusual noise can be heard during operationElectrical Schematic Diagram Indoor Unit Please Insert Diagram in hereElectrical Schematic Diagram Electrical Schematic Diagram Outdoor Unit Please Insert Diagram in hereWarranty